![Sensor SMT-200 Operation And Technical Manual Download Page 39](http://html1.mh-extra.com/html/sensor/smt-200/smt-200_operation-and-technical-manual_1243987039.webp)
Io
SENSOR
Section 2 SMT-200 Operations
SMT-200 Operations and Technical Manual 2.00/R1
29
Temp
Manually enter the string temperature in
o
C.
Ref. Geo Temp
.
Read and store the temperature using the supplied
reference geophone.
Smartec
Turns the Smartec on or off.
Smartec Temp.
Read and store the temperature using the external
Smartec.
NOTE:
When manually entering the temperature make sure that use of the temperature sensor is
disabled (Temperature command 3). All following measurements will be corrected with the entered
value.
The SMT-200 automatically corrects the display contrast setting according to temperature measured
and indicated in system temperature.
Temperature command 2 allows you to measure the temperature with the use of the supplied
reference geophone. The SMT-200 measures the coil resistance of the reference geophone.
Assuming any deviation from the nominal value at 20°C is due to temperature variation the actual
temperature can be calculated.
There is a Smartec temperature sensor built into the Bendix connector of the SMT-200. It is important
to make sure that the temperature of this connector is the same as the temperature of the geophones
under test. See Smartec connections in appendix A for further details.
The cable which connects the SMT-200 with the Docking Station does not have a built-in Smartec
sensor. The 1 m cable supplied with a Smartec sensor and RJ-11 connector at the other end provides
the SMT-200 with an identical temperature measurement option when it is connected to the Docking
Station.
When Smartec temperature measurement is enabled, choosing Temperature command 4 will refresh
the displayed temperature. In normal use the SMT-200 will automatically measure and update the
temperature every minute. If a test is being run at that time the update is due then the temperature will
be updated at the end of the test.
Temperature menu
----------------
1>Temp 20.0 °C
2 Ref. Geo Temp.
3 Smartec ON
4 Smartec Temp.
0 Back to main
----------------
Enter / display
string temp.
3>Temp. menu…