SENSORPROX 100R/PIN120 - 

SINGLE DOOR CONTROLLER 

 

 

 

 

 

 

 

 

1. IMPORTANT SAFETY INSTRUCTIONS 

 
When using your Single Door Controller, basic safety precautions should always be followed to reduce the risk of fire, electrical 

shock, and injury to persons. In addition, the following should also be followed: 
 

1. Read and understand all instructions.   
2. Follow all warnings and instructions marked on the product. 

3. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. If necessary, use mild soap. 
4. Do not use this product near water, such as bath-tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or swimming pool. 

5. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the 

type of power supplied to your installation site, consult your dealer or local power company. 

6. Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts 

that could result in fire or electric shock. Never spill liquid of any kind on the product. 

7. To reduce the risk of electric shock, do not disassemble this product by yourself, but take it to qualified service whenever service 

or repair is required. Opening or removing the covers may expose you to dangerous voltages or other risks. Also, incorrect 

reassembly can cause electric shock when the unit is subsequently used. 

8. Unplug this product from the Direct Current (DC) power source and refer to qualified service personnel under these    conditions: 

a.  When the power supply cord or plug is damaged or frayed. 
b.  If liquid has been spilled on the product. 

c.  If the product does not operate normally after following the operating instructions in this manual. 

Adjust only those controls that are covered by the operating instructions in this manual. Improper adjustment of other controls 

that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to 
restore normal operation. 

d.  If the product exhibits a distinct change in performance. 

 
 

2. GENERAL 

 

A properly configured SENSORPROX 100R/PIN120 is an intelligent single door controller that combines the convenience of wireless 
entry with the security of an alarm system. Also, the SENSORPROX 100R/PIN120 system will give you field proven reliability and 

cost-effective solution anywhere access controls and high security are required. Each standard unit can store up to 512 users or card 
Ids.    The task of assigning cards and managing a user’s database is so simple, user friendly, and can be accomplished in many 

ways; it could be as simple as presenting each card to the unit or as descriptive as a user’s database with an easy to use Graphical 
User Interface. 

 
The SENSORPROX 100R/PIN120 can interface and operate with these accessories: Request for EXIT button, Door-Contact sensor, PIR 

sensor, Fire sensor and other sensors via 5 independent input ports. Also, output ports which include 2 Relays and 2 TTL outputs can 
be used to control the operation of other accessories such as Electric/Magnetic Door Lock, Alarm, Chime Bell, and Auto-Dialer. 

Moreover, the status or behaviors of these input and output accessories are configurable to provide the system administrator with 
complete customized control of the system. Besides the above configurable I/O interfaced behaviors, many of the SENSORPROX 

100R/PIN120 internal behaviors are programmable as well.   

 
The internal operating parameters include the number of incorrect access attempts before alarm condition is triggered, tampering 

protection from mounting removal, and timers. Furthermore, every event or transaction can be captured and time stamped by the 
SENSORPROX 100R/PIN120 application software via the provided RS-232 wires. 

Summary of Contents for SENSORPROX 100R/PIN120

Page 1: ...SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 1 USER MANUAL...

Page 2: ...ral 3 3 Features 4 4 Specification 4 5 Front Panel Description 5 6 Identifying Supplied Parts 5 7 Installation of the Product 6 8 Color Coded Wiring Table 7 9 System Wiring for Typical Application 8 1...

Page 3: ...he operating instructions in this manual Improper adjustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician t...

Page 4: ...in method is employed RS 232 communication port for interfacing with the SENSORPROX 100R PIN120 application software 3 LEDs red green and yellow for system operation status Chime Bell function to ope...

Page 5: ...120 SINGLE DOOR CONTROLLER 5 5 FRONT PANEL DESCRIPTION SENSORPROX 100R PIN120 Main Unit 6 IDENTIFYING SUPPLIED PARTS Please unpack and check the contents of the box MainUnit Wall Mount O Ring Manual 1...

Page 6: ...CAUTIONS Before mounting the SENSORPROX 100R PIN120 unit to the Wall Mount bracket operational testing of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing...

Page 7: ...larm RELAY 2A COM White wire Alarm RELAY 2A NC Purple wire with White band Alarm RELAY 2A NO Purple wire TTL Output TTL Orange wire with White band CHIME BELL Output BELL Brown wire with White band IN...

Page 8: ...re to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY COM Grey Red banded wire Connec...

Page 9: ...then see section 12 69 to change the detection scheme from the defaulted setting 9 6 Auxiliary Input Device Connection Applied to AUX Input 1 2 3 Connect one wire of the Auxiliary Input Device to the...

Page 10: ...232 Communication Port Connection 9 pin connector COM Port female is required to connect serial communication RS 232 between Main Unit and Personal Computer Connect RS 232 TX Grey wire of Main Unit t...

Page 11: ...figuration Card and the following RF Cards are registered as User Access Cards Once all User Access Cards have been registered present the Configuration Card again to complete the registration Please...

Page 12: ...again to complete the registration Please store the Configuration PIN for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 4 Factory Defa...

Page 13: ...nd 11 2 Open the Door When a registered Card or PIN is read the Door will open for 3 seconds along with the do mi sol do melody Registered Card or PIN 11 3 Exit Open the Door To request for exit from...

Page 14: ...e key can be used to activate an external Chime Bell for 5 seconds the defaulted value 12 SETTING CHANGES Configuration Card PIN is required to change existing or defaulted setting values or to manage...

Page 15: ...Enable QUICK ACCESS MODE 44 Disable QUICK ACCESS MODE 51 Disable Melody sound turning off both the melody keypress audio feedback 52 Enable Melody sound 60 Change keypad lock out time when Try Out er...

Page 16: ...ration Card 12 12 Add User Access Cards RF CARD PIN MODE Configuration Card Command Cards to be registered Configuration Card 12 13 Add User Access PIN PIN ONLY MODE Configuration PIN Command PINs to...

Page 17: ...tivate only Alarm Relay 02 Activate only TTL Output 04 Activate Door Relay TTL 05 Activate Alarm Relay TTL 06 EX1 Activate Door Relay In Safe Secure Mode Safe Secure Mode 50 Door Relay 01 OM 51 EX2 Ac...

Page 18: ...r Detected Refer to Table 1 for OM tt 00 99 sec Defaulted Alarm time 10 sec Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 24 Change Alarm Time When Door Con...

Page 19: ...ote 00 is registered as defaulted Password 12 30 Change Alarm Time When Duress Alarm Detected tt 00 99 sec Defaulted TTL time 03 sec Configuration Card Command TTL time Configuration PIN 12 31 Test Do...

Page 20: ...CK ACCESS MODE When QUICK ACCESS MODE is enabled Door will open simply by press key Configuration Card Configuration PIN 12 44 Disable QUICK ACCESS MODE Configuration Card Configuration PIN Defaulted...

Page 21: ...Card Configuration PIN 12 65 Set AUX 3 Input Detection from L to H AUX 3 input is detected on the raising edge of AUX 3 input Configuration Card Configuration PIN 12 66 Set AUX 3 Input Detection from...

Page 22: ...te from logic 1 to logic 0 when it activates Defaulted setting Configuration Card Configuration PIN 12 77 Enable Chime Bell Output Configuration Card Configuration PIN Defaulted setting Enable 12 78 D...

Page 23: ...t Tamper Alarm Output Port Refer to Table 1 for OM Defaulted Output port 02 Alarm Relay Configuration Card Command Alarm Output Port Configuration PIN 12 88 Enable Tamper Alarm To comply with UL 294 t...

Page 24: ...nput To Enter ID Number Keypad input is enabled to enter the ID numbers through keypads Configuration Card Configuration PIN 12 74 Disable Keypad Input To Enter ID Number Keypad input is disabled to e...

Page 25: ...A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wit...

Page 26: ...SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 26 15 TEMPLATE...

Reviews: