SENSORPROX 100R/PIN120 -
SINGLE DOOR CONTROLLER
12
(5) Now, the Main Unit is entered into the normal operation mode with factory defaulted settings.
10-3. Registration of PIN ONLY MODE
(1) Apply 12VDC to the unit.
All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).
(2) Press from the keypad. (PIN ONLY MODE)
(3) Enter to register Configuration PIN then to register for
each subsequent User Access PIN at a time and then enter the
(Configuration PIN) to complete the registration.
……..
Configuration PIN User Access PIN... Configuration PIN again
to
complete
the
registration.
(4) The first 4~6 digit PIN becomes the Configuration PIN and the subsequent 4~6 digit PINs are
registered as User Access PINs. Once all User Access PINs have been registered, enter the
Configuration PIN again to complete the registration. (Please store the Configuration PIN for future
changes.)
(5) Now, the Main Unit is entered into the normal operation mode with factory defaulted settings.
10-4. Factory Defaulted Setting Values
After the Initial Setup, the Main Unit uses the factory defaulted setting values below to execute the normal
operation mode. You may want to change these factory setting values or modify your User Access list; refer
to section 12 for instructions on how to customize the operation of your unit.
(1) When User Access Card (or PIN) is granted
- Door RELAY activates for 3sec.
- Green LED lights on for 3sec.
(2) When User Access Card (or PIN) is not recognized
- Alarm RELAY activates for 2sec.
- Red LED lights on for 2sec.
(3) Duress Password = 00, Duress Alarm to TTL output port for 03 sec.
(4) QUICK ACCESS MODE = Disable
(5) Chime Bell output = Enable, Chime Bell activation time = 05 sec.
(6) Melody sound = Enable
(7) Keypad lock-out time when Try-Out error detected = 01 min.
(8) Detect all inputs from ‘H’ to ‘L’