SENSORPROX 100R/PIN120 -
SINGLE DOOR CONTROLLER
10
9-8
. Wiegand Input Connection From Another Compatible Wiegand Reader
(Separate purchase required)
- Connect (+) wire of Reader to DC +12V (be sure that the existing power supply has enough capacity
to support this accessory or upgrade to a sufficient one.)
- Connect (-) wire of Reader to Power GND (-) wire.
- Connect Wiegand output DATA0 wire of the additional Reader to DATA0, Pink wire.
-
Connect Wiegand output DATA1 wire of the additional Reader to DATA1, Cyan wire.
9-9. RS-232 Communication Port Connection
9-pin connector (COM Port, female) is required to connect serial communication RS-232 between Main Unit
and Personal Computer.
- Connect RS-232-TX, Grey wire of Main Unit to pin number 2 of 9-pin connector.
- Connect RS-232-RX, Blue wire of Main Unit to pin number 3 of 9-pin connector.
- Connect RS-232-GND, Yellow wire of Main Unit to pin number 5 of 9-pin connector.
- Plug in 9-pin connector to COM1 or COM2 Port of Personal Computer.
- Install and run SENSORPROX 100R/PIN120 Application Software.
9-10. Chime Bell Connection
(Separate purchase required)
- Connect (+) wire of Chime Bell unit to Bell Output, Brown/White wire of Main Unit.
- Connect (-) wire of Chime Bell unit to Power GND (-) wire.