SENSORPROX 100R/PIN120 -
SINGLE DOOR CONTROLLER
15
24
Change Alarm time when Door-Contact error detected
25
Change Alarm time when Aux Input #1 detected
26
Change Alarm time when Aux Input #2 detected
27
Change Alarm time when Aux Input #3 detected
28
Change Alarm time when magnet detected
29
Register 2 digits Duress Alarm password
30
Change Alarm time when Duress Alarm detected
31
Test Door open time set by command "21"
32
Test Alarm time set by command "22"
33
Test Alarm time set by command "23"
34
Test Alarm time set by command "24"
35
Test Alarm time set by command "25"
36
Test Alarm time set by command "26"
37
Test Alarm time set by command "27"
39
Change Chime Bell activating time
41
Open door unconditionally
42
Close door unconditionally
43
Enable QUICK ACCESS MODE
44
Disable QUICK ACCESS MODE
51
Disable Melody sound (turning off both the melody & keypress audio feedback)
52
Enable Melody sound
60
Change keypad lock-out time when Try-Out error detected
61
Set Aux Input #1 Detection from ‘L’ to ‘H’
62
Set Aux Input #1 Detection from ‘H’ to ‘L’
63
Set Aux Input #2 Detection from ‘L’ to ‘H’
64
Set Aux Input #2 Detection from ‘H’ to ‘L’
65
Set Aux Input #3 Detection from ‘L’ to ‘H’
66
Set Aux Input #3 Detection from ‘H’ to ‘L’
67
Set Exit Button Input Detection from ‘L’ to ‘H’
68
Set Exit Button Input Detection from ‘H’ to ‘L’
69
Set Door-Contact sensor Input Detection from ‘L’ to ‘H’
70
Set Door-Contact sensor Input Detection from ‘H’ to ‘L’
71
Activate TTL output to ‘H’
72
Activate TTL output to ‘L’
77
Enable Chime Bell Output
78
Disable Chime Bell Output
80
Set delay time to activate SECURE MODE
81
Set Door Open time-out for Door-Contact sensor
82
Set number of times of Try-Out
83
Set input keypress time-out time