CI
2 x PCMCIA CI slots
CAM
Descrambled channel quantity
depends on CAM capability, 2 CAMs
could be different
Frequency Range
47 ~ 862MHz
Bandwidth
6/7/8MHz
Constellation
DVB-T: QPSK / 16QAM / 64QAM
DVB-T2: QPSK / 16QAM / 64QAM /
256QAM
Guard Interval
DVB-T: 1/4, 1/8, 1/16, 1/32
DVB-T2: 1/4, 1/8, 1/16, 1/32, 1/128,
19/256, 19/128
FFT Size
DVB-T: 2K, 8K
DVB-T2: 1K, 2k, 4K, 8K, 16k, 32K
Signal Level
-80~-20dBm
CA system
Supports mainstream CAS
DVB-S/S2 with CI Receiver
Input
C/Ku Band, 4 channels via 2 RF
Female connectors
CH1 & CH2 via LNB-1
CH3 & CH4 via LNB-2
LNB Power
Independent power supplies for each
LNB
LNB Voltage
13V / 18V
LNB Current
Max. 400mB
CI
2 x PCMCIA CI slots
CAM
Descrambled channel quantity
depends on CAM capability, 2 CAMs
could be different
Constellation
QPSK, 8PSK
Frequency Range
950 - 2150MHz
Signal Level
-70~-20dBm
Roll-off Factor
0.15, 0.20, 0.25, 0.35
Symbol Rate
DVB-S: 1~45Msps
DVB-S2: 1~45Msps
FEC
DVB-S: 1/2, 2/3, 3/4, 5/6, 7/8
DVB-S2: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6,
8/9, 9/10
CA System
Supports mainstream CAS