OmniHub CMP100 – User Manual
Page
89
of
106
5. Make sure Client 0 is enabled and then input the unicast of multicast address into
the “Remote Host Unicast or Multicast IP Address” text box. It is suggested the
unicast normally be used, so what should be put in this box is the management
IP address of the CMP100. It is also possible to input a multicast address
(224.x.x.x – 239.x.x.x).
6. Make sure the “Remote Host Port” is configured to be 5050 as this is the default
port for SCTE18 messages and it is not planned to have the CMP100 listen for
SCTE18 messages on any other port.
7. Also make sure the
In-Band
checkbox is disabled. The CMP100 will be using
the Out-Of-Band PID = 0x1FFC.
8. Another very important configuration is that the
Alert Repeat Control
must be
set to “Always repeat alert send” and the
Alert Message Repeat Period
should
be set to 6 seconds.