SERVICE | Service and Maintenance
Doc #OI0003 Part #004122 Rev 04 2010
|
115
Monitoring the Operation of your SP PRO
The following items should be monitored on a regular basis:
•
BATTERY VOLTAGE
- this should
NEVER
be below the nominal system voltage, e.g. 24V, 48V or 120V
•
BATTERY SoC%
- a high average figure will maintain battery life
•
The AVERAGE DAILY ENERGY SUPPLIED
to the load (Load kWh/Day), the lower this figure is, the less
recharging will have to take place, this will maximize battery life
•
EVENT LOG
– unexpected events.
•
SYSTEM TEMPERATURES
should be kept as low as possible.
Maintenance of your SP PRO
Very little is required in order to maintain your SP PRO, however, partaking in the following steps will ensure
smooth operation of the system.
• Cleaning. Large particles of dirt can be removed with a soft brush or similar implement. Dust can be
removed with a damp cloth. Solvents, abrasives or corrosive chemicals must not be used for cleaning.
• When the fan filter requires cleaning the Service Required LED will illuminate. Check in the NOW tab of
the DATA VIEW section to determine what type of service is required.
All other maintenance on your SP PRO should be performed by a Selectronic Accredited Installer.