43
1.8 IP Protection rating
S
IP23S
- Enclosure protected against access to dangerous parts by fin-
gers and against ingress of solid foreign bodies with diameter
greater than/equal to 12.5 mm
- Enclosure protected against rain at an angle of 60°.
- Enclosure protected against harmful effects due to the ingress
of water when the moving parts of the equipment are not
operating.
2 INSTALLATION
Installation should be performed only by expert
personnel authorised by the manufacturer.
During installation, ensure that the power source
is disconnected from the mains.
The multiple connection of power sources (series
or parallel) is prohibited.
2.1 Lifting, transport & unloading
- The equipment is provided with a handle for hand transportation.
- The equipment is not equipped with specific lifting elements.
Use a fork lift truck paying attention during operations in
order to prevent the generator from tipping over.
Do not underestimate the weight of the equip-
ment: see technical specifications.
Do not move or position the suspended load
above persons or things.
Do not drop or apply undue pressure on the
equipment.
Do not lift the unit by the handle.
2.2 Positioning of the equipment
Keep to the following rules:
- Provide easy access to the equipment controls and connec-
tions.
- Do not position the equipment in very small spaces.
- Do not place the equipment on surfaces with inclination
exceeding 10° from to the horizontal plane.
- Position the equipment in a dry, clean and suitably ventilated
place.
- Protect the equipment against pouring rain and sun.
2.3 Connection
The equipment is provided with a power supply cable for con-
nection to the mains.
The system can be powered by:
- mono-phase 230V
CAUTION: to prevent injury to persons or damage
to the equipment, the selected mains voltage and
fuses must be checked BEFORE connecting the
machine to the mains. Also check that the cable is
connected to a socket provided with earth contact.
Operation of the equipment is guaranteed for volt-
age tolerances up to ±15% with respect to the
rated value.
The equipment can be powered by a generating set
guarantees a stable power supply voltage of ±15%
with respect to the rated voltage value declared by
the manufacturer, under all possible operating condi-
tions and at the maximum rated power.
Summary of Contents for Genesis 2200 PMC
Page 1: ...Genesis 2200 PMC MANUALE DI RIPARAZIONE REPAIR MANUAL...
Page 38: ...74...
Page 41: ...77 16 SCHEMI ELETTRICI E DI COLLEGAMENTO WIRING DIAGRAMS AND CONNECTION...
Page 42: ...78 17 CONNETTORI CONNECTORS...
Page 43: ...79...
Page 44: ...80 18 LISTA RICAMBI SPARE PARTS LIST 55 05 010 GENESIS 2200 PMC 1x230V...
Page 47: ...83...
Page 48: ...84 07 01 600 SL 4R 4T 11A 11B 11C 22...
Page 50: ...86 19 INSTALLAZIONE KIT ACCESSORI INSTALLATION KIT ACCESSORIES 73 11 014 Kit Push Pull...
Page 51: ...87...
Page 52: ...88 STANDARD U D VERSION OPTIONAL PUSH PULL VERSION...
Page 53: ...89...
Page 54: ...90 MODULO RICAMBI...