10) CALIBRATIONS
Calibrations procedure
Following description is for calibration procedure, for
offset signal and gain signal.
The offset calibration (set.up 704)
should be performed in case of complete or partial sw reflashing , or in case the measurement
in no load circuit are different from “0”. The calibration is not required in case of pcb replacement (boards are just Factory cali-
brated) or first customers setting.
The gain calibration (set.up 701)
should be performed only if the real output parameters exceed the maximum tolerance admitted
(± 2,5% maximum rated welding current).
10.1) Offset calibration (set-up 704)
Lets you calibrate the system.
Short circuit the system’s
and
connectors.
Enter set-up by pressing the encoder key for at least 5 seconds. Select the required parameter (704).
Press the encoder knob to perform calibration.
Repeat the calibration process if you update the software (DSP).
Repeat the calibration process if you change the control card (DSP).
10.2) Voltage calibration (set-up 702)
Lets you calibrate the system.
Enter set-up by pressing the encoder key for at least 5 seconds. Select the required parameter (702).
Press the encoder knob to perform calibration.
Use a tester to read the real voltage value.
V
TAR = 35V
Turn the encoder knob of the machine until clamp meter display 35V. Press the encoder button to end calibration.
Summary of Contents for Genesis 2200 PMC
Page 1: ...Genesis 2200 PMC MANUALE DI RIPARAZIONE REPAIR MANUAL...
Page 38: ...74...
Page 41: ...77 16 SCHEMI ELETTRICI E DI COLLEGAMENTO WIRING DIAGRAMS AND CONNECTION...
Page 42: ...78 17 CONNETTORI CONNECTORS...
Page 43: ...79...
Page 44: ...80 18 LISTA RICAMBI SPARE PARTS LIST 55 05 010 GENESIS 2200 PMC 1x230V...
Page 47: ...83...
Page 48: ...84 07 01 600 SL 4R 4T 11A 11B 11C 22...
Page 50: ...86 19 INSTALLAZIONE KIT ACCESSORI INSTALLATION KIT ACCESSORIES 73 11 014 Kit Push Pull...
Page 51: ...87...
Page 52: ...88 STANDARD U D VERSION OPTIONAL PUSH PULL VERSION...
Page 53: ...89...
Page 54: ...90 MODULO RICAMBI...