71
800 Read
filter
Lets you filter current and voltage readings.
Minimum 1, Maximum 5, Default 1
802 Starting
filter
Allows the control of the guard limits to be enabled with an adjustable delay in relation to the arc striking.
Makes it possible to filter the striking phase (consult the “Guard limits” section).
Minimum 0.0s, Maximum 10.0s, Default 2.0s
803 Output
filter
Makes it possible to disenable the control of the guard limits in advance of the natural closing of the weld.
Makes it possible to filter the extinction phase (consult the “Guard limits” section).
Minimum 0.0s, Maximum 10.0s, Default 2.0s
12.3) “INFO” screen (set-up 501)
Allow to display of a series of system data.
1
System type board
2 Board
Control board
3 Software
Software version (Control board)
4 S/N
Serial number
5 Power supply Power supply
6 Working time System operation time
7 Welding time System welding time
8 Gain adjust
Calibration of the system
9
μ
P
Microprocessor
10 DSP
DSP (Digital signal processor)
11 FP
Control panel
12 WF
Wire feeder
13 WU
Cooling unit
14 RC
Remote control
15 RI
Robot interface
16 PC
PC interface
17 ST
TIG Torch
18 MB
MIG/MAG torch
19
Software
versions
The lack of the software version shown alongside a device (---) indicates lack of communication with it, and correct operation is
therefore not guaranteed (consult the “Diagnostics and solutions” section).
Summary of Contents for Genesis 2200 PMC
Page 1: ...Genesis 2200 PMC MANUALE DI RIPARAZIONE REPAIR MANUAL...
Page 38: ...74...
Page 41: ...77 16 SCHEMI ELETTRICI E DI COLLEGAMENTO WIRING DIAGRAMS AND CONNECTION...
Page 42: ...78 17 CONNETTORI CONNECTORS...
Page 43: ...79...
Page 44: ...80 18 LISTA RICAMBI SPARE PARTS LIST 55 05 010 GENESIS 2200 PMC 1x230V...
Page 47: ...83...
Page 48: ...84 07 01 600 SL 4R 4T 11A 11B 11C 22...
Page 50: ...86 19 INSTALLAZIONE KIT ACCESSORI INSTALLATION KIT ACCESSORIES 73 11 014 Kit Push Pull...
Page 51: ...87...
Page 52: ...88 STANDARD U D VERSION OPTIONAL PUSH PULL VERSION...
Page 53: ...89...
Page 54: ...90 MODULO RICAMBI...