66
10.3) Current calibration (set-up 701)
Connect the outlet connections on a static load properly sized.
I = 200A
V = 28V
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (701).
Press the encoder knob to perform calibration.
Use a clamp meter to read the real current value.
Turn the encoder knob of the machine until clamp meter display 200A.
Press the encoder button to end calibration.