67
11) ALARMS TROUBLESHOOTING
Alarms
Description
Possible cause
Checks
E01
Temperature alarm 1
NTC primary side alarm.
- If the alarm is tripped for a
temperature rise due to extra
duty cycle working time at
high currents, wait for the coo-
ling of the generator. With the
generator turned on, the fans
work to speed up the cooling
of the generator.
- If the alarm is present just
switching on generator (status
"cold") the NTC1 is defecti-
ve or a cable connection is
disconnected.
See "Test on Primary Thermic
sensor ”.
E02
Temperature alarm 2
Thermic T1 primary side
alarm.
- If the alarm is tripped for a
temperature rise due to extra
duty cycle working time at
high currents, wait for the coo-
ling of the generator. With the
generator turned on, the fans
work to speed up the cooling
of the generator.
- If the alarm is present just
switching on generator (status
"cold") the T1 is defective or
a cable connection is discon-
nected.
See "Test on Primary Thermic
sensor ”.
E07
Wire feed motor supply alarm Motor's power supply failure.
- Perform checks on motor card
and power supply card.
E08
Blocked motor alarm
There was an engine block or
missing encoder signal.
- Checks properly encoder fit-
ting, winding and rollers area.
E10
Power module alarm
Presence of fast over -current
on inverter or pfc .If the pro-
blem persist indicate a short
circuit presence on power
stage.
- Perform checks on primary
inverter section and secondary
rectifier.
- Check output rectifier diodes.
E13
Communication alarm (FP)
CAN BUS communication
with front panel missing.
Could be also intend as over-
load peripheral can-bus. The
digital card doesn’t recognize
the front panel.
- Perform test on front panel.
- If problem remain is sugge-
sted to disconnect all possi-
ble can bus user’s as WU-RC.
Check integrity of cable to
front panel.Perform test and
in case repair digital pcb.
15.14.533.
E19
System configuration alarm
- Internal software doesn’t
match.
- Control software relea-
se (par.501 pwd 358 set.up
serv).
Repeat download software:
contact service Selco.
A reset is suggested.
In case the problem persist
repair 15.14.533 pcb.
Summary of Contents for Genesis 2200 PMC
Page 1: ...Genesis 2200 PMC MANUALE DI RIPARAZIONE REPAIR MANUAL...
Page 38: ...74...
Page 41: ...77 16 SCHEMI ELETTRICI E DI COLLEGAMENTO WIRING DIAGRAMS AND CONNECTION...
Page 42: ...78 17 CONNETTORI CONNECTORS...
Page 43: ...79...
Page 44: ...80 18 LISTA RICAMBI SPARE PARTS LIST 55 05 010 GENESIS 2200 PMC 1x230V...
Page 47: ...83...
Page 48: ...84 07 01 600 SL 4R 4T 11A 11B 11C 22...
Page 50: ...86 19 INSTALLAZIONE KIT ACCESSORI INSTALLATION KIT ACCESSORIES 73 11 014 Kit Push Pull...
Page 51: ...87...
Page 52: ...88 STANDARD U D VERSION OPTIONAL PUSH PULL VERSION...
Page 53: ...89...
Page 54: ...90 MODULO RICAMBI...