STP-H803/H1303 Series Instruction Manual
LCD Messages
Probable Causes
Countermeasures
Referred
Section
TMS Higher Temp.
TMS temperature control error
(when the TMS unit detection
temperature b10°C or
more):
1) Insufficient cooling of the
TMS unit
2) Failure of the TMS unit
1) Connect the cooling
water
electromagnetic
valve correctly.
Check the amount
and the temperature
of cooling water.
2) Contact Service
office.
Instruction
Manual of
TMS Unit
Malfunction
information
TMS Lower Temp.
TMS temperature control error
(when the detection temperature
of the TMS unit becomes -10°C or
less: such error cannot be
detected within 1 hour after
startup):
1) Failure of the TMS heater
2) Failure of the TMS unit
1) Contact Service
office.
2) Contact Service
office.
Malfunction
information
Malfunction
information
TMS overheat
Overheat of the TMS heater:
1) Failure of the TMS heater
2) Failure of the TMS unit
1) Contact Service
office.
2) Contact Service
office.
Malfunction
information
Malfunction
information
Tuning Error 1
Tuning Error 2
Tuning Error 3
Tuning Error 4
Tuning Error 5
Tuning errors
"No LEVITATION" is
displayed.
Perform tuning again after
turning on the power.
9.1
w
(appears on the upper
right LCD display)
When any warning message
appears on the LCD display.
Refer to the respective
warning message.
11.4
Troubleshooting
11-7