16
5. Assembly, installation
A / 24.08.15 - OM.INS.10EN - 2/2
Ensure that the drives are seated correctly.
–
Shifting of the drive during transport/installation of the pump must
be compensated for by aligning/securing the drive.
Attach protective devices and make sure they are functioning.
5.4
Adjust and connect pipelines
Refer to the dimensional drawing (
chapter 5.6) and the technical data
(
chapter 3) for the position, nominal width and standard for the intake and
pressure connection.
Comply with the specified screw tightening torques (
chapter 9).
5.4.1
Check pipeline dimensioning
Note technical data (
chapter 3).
–
Adhere to specifications regarding pressure in the pressure respectively
suction connection.
–
Nominal width of suction pipe = nominal width of suction connection of
pumps.
5.4.2
Check that the pipelines are free of residue
Damage to property due to assembly residues in the pipeline and
machine. Keep all pipelines free from foreign bodies. Remove welding
spatter, screws, steel chips, etc.
5.4.3
Assemble pipeline tension-free
Assemble pipelines and other components in a tension-free manner on the
pump.
5.5
Assemble liquid connections for add-on devices (optional)
Refer to technical data (
chapter 3) for type of additional device.
Refer to chapter options and accessories (
chapter 12.1) for technical de-
scription of additional devices.
5.6
Connect the power supply
DANGER
Risk of fatal injury from electrical current.
There is an immediate danger of fatal electric shock through contact with live
parts.
Observe applicable safety regulations.
Prevent electrical connections from being switched on again.