5. Assembly, installation
A / 24.08.15 - OM.INS.10EN - 1/2
5.
Assembly, installation
5.1
Safety during assembly and installation
5.2
Determine the space requirement
Define the space required based on the following factors:
•
Dimensions and weight of the machine
•
Required transport and hoisting devices
•
Freedom of movement to:
–
Operate the drive
–
Read rotation speed and pressure displays
–
Set the retensioning device (optional)
–
Operate the seal flush supply system (optional)
•
Space required for lubrication processes / lubricant replacement
•
Dismantling of mechanical protective devices
•
Required space for assembly work on the machine
Space requirement for service and setting work on SCT pumps:
5.3
Assemble the complete mounted pump
Assemble the pump in compliance with the technical data (
chapter 3)
and the specifications in the dimensional drawing (
chapter 5.6).
Comply with the specified screw tightening torques (
chapter 9).
Assemble the pump tension-free.
–
For assembly on foundations or load-bearing elements, compensate for
any unevenness with suitable supports to ensure that all pump support
surfaces are solidly seated.
CAUTION
Risk of injury due to improper assembly and installation of the machine.
Improper installation of the machine can lead to minor injuries and significant
damage to property.
Before starting work, ensure there is sufficient space for assembly.
Ensure that the assembly location is clean and tidy. Loose components and tools lying on top of one
another or left around the area are potential sources of accidents.
Assemble the machine correctly.
Size
Distance (P)
2-12S
300 mm
5-12S
315 mm
10-12S
350 mm
17-12S
375 mm
35-12S
430 mm
52-12S
530 mm
70-12S