30
9.1 Dismantling
A / 07.11.2019 - OM.SCT.BN.S03EN
3/36
Recommended auxiliary materials
Keep the auxiliary materials listed available (not included in the scope of delivery):
Lubricant
(GM)
9.1.2 Prepare pump for dismantling
Follow the instructions in the chapter Shut-down (
chapter 6).
9.1.3 Dismantle pump
Mounting lever
(W9)
Dismantling tool
(W10)
Illustration
Denomination
NOTICE
Damage to property due to inadequate lubricants (GM).
Damage to components. Contamination of the conveying medium.
Observe resistance to the materials used and the conveying medium.
Use suitable lubricants
(GM)
only.
Risk of injury due to lack of stability of
pump. Crushing of body parts due to the pump or
pump parts tipping or falling down.
Fasten base plate
(GPU)
to secure pump.
–
Recommendation: Fasten to suitable base
using a screw fitting
(SCH)
.