56
9.2 Reassembly
A / 07.11.2019 - OM.SCT.BN.S03EN
29/36
Assemble the flush connection (SSU) (optional)
9.2.3.4 Assemble suction casing (500)
9.2.3.5 Assemble pressure branch (700)
Assemble flush connection
(SSU)
.
Push on casing gasket
(501)
.
Assemble and align suction casing
(500)
with
screw fitting
(506, 507, 509)
.
–
Use spirit level
(WW)
.
Assemble screw fitting
(SCH)
on trestle
(607)
.
Assemble pressure branch
(700)
with screw
fitting
(SCH)
to base plate
(GPU)
.