CRACK PRO® HEATED HOSE MACHINE
OPERATING INSTRUCTIONS – DOUBLE PUMPER
OPTIONAL
THE TEMPERATURE CONTROL
4.
To stop for the day, perform the following steps:
Shut
the agitator control valve.
Put the hose enable/disable switch(s) to the
disable
position.
Turn the pump switch(s) to reverse for 30 seconds, then
turn to the
off
position.
Turn the burner control switch to the
off
position.
Shut off the engine.
AUTOMATIC SAFETY INTERLOCKS:
There are automatic safety interlocks that
control the heated hose, material pump, and agitation systems. The agitator and
pump
will not
work until the material has reached a pre-programmed
temperature on the respective digital controllers. The heated hose must also be
up to temperature before the pump can operate.
Once the 3 controllers reach the programmed temperature settings the
white interlock light comes on,
the agitator control valve will need to be
started manually.