16
CRACK PRO® HEATED HOSE MACHINE
OPERATING INSTRUCTIONS
FLUID SPECIFICATIONS
Diesel engine crankcase oil:
The break-in oil should be changed after the first 50 hours of operation.
Oil change intervals:
Temperature
Oil type
Interval
Above 77°F
SAE 30 or 10w-30
with filter 100 hours
Between 32°F to 77°F
SAE 20 or 10w-30
with filter 100 hours
32°F or below
SAE 10 or 10w-30
with filter 100 hours
Hydraulic oil:
The hydraulic system should be drained, cleaned, and refilled every
two years.
If the oil becomes contaminated at any time, flush the system
immediately. The oil filter should be changed yearly.
System capacity is 30 gallons.
Change the hydraulic oil filter after the first 20 hours of operation.
The factory installed oil meets the following specifications:
Grade 68
Viscosity @ 100°F SUS 306
Approximate SAE grade 20W
Factory installed oil: COMMERCIAL AW Hydraulic Oil
See enclosed MSDS