SD-EN-030 38 / 40 V1.0
7.7.
Unable to control the G265 system with a 3
rd
party controller
1.
Ensure that the 3rd party controller is connected into the same network as the G265 system.
2.
Check if the 3
rd
party controller sends commands out via UDP.
7.8.
Unable to use signals from RTSP streaming/RTSIP IP ouputs grey screen
1.
Ensure the parameters for the additional device is entered correctly (IP address/Main/sub-stream
addreess) (User can check the stream address using the Potplayer/VLC software.)
2.
Ensure that the output resolution does not exceed the decoding limitation of the transceiver..
3.
Ensure that the IP switch and CAT meets the minimum requreiment.
7.9.
Outputs on the output panel does not perform properly
1.
Ensure that the resolution of the outputs on the output panel does not exceed the decoding
limitation of the transceiver.
2.
Ensure that the IP switch and CAT meets the minimum requirement as specified.
7.10.
The Default Design is disarranged and not working anymore
1.
Open the file called ‘Draft_0’ in the downloaded software p
ackage with the G265 Designer
Software. It will restore all settings in the G265 Designer Software to the default design when it
was downloaded.
2.
Re-download the software from our website.
SEADA are always available to offer support, including full online training videos, webinars and
more advanced 1 to 1 training. If you do need to contact us, please get in touch through our
phone, the number is +44 01527 584364 or send us an email at