| P
age 61
|
SEABOB
Operation
Manual
|
6
2. Remove the sealing cap and the washers from the at-
tachment screw.
3. Slide the fixing eyelet of the new sealing cap and the
washers all the way onto the M4 x 16 screw in the fol-
lowing order: a) the first stainless steel washer, b) the
fixing eyelet of the sealing cap, c) the second stainless
steel washer, d) the plastic washer.
4. Before screwing in the attachment screw, apply a
small amount of Klüber Staburags NBU 30 PTM lubri-
cating grease to the threads of the screw.
5. Tighten the M4 x 16 attachment screw using the Allen
key (size 3).
6. Check that the sealing cap is seated properly, and in-
sert the clean and dry sealing cap securely into the
charging socket of the accumulator box.
On models with Accumulator Change System (SEA-
BOB CAYAGO VX2 and SEABOB CAYAGO F7 models):
Before changing the sealing cap, you must remove the
quick clamp system mounted above it. To do this, re-
move the four attachment screws (M5 x 10 stainless
steel countersunk screws with hex socket) on the attach-
ment plate of the quick clamp system using an Allen key
(size 3). Apply a small amount of Klüber Staburags NBU
30 PTM lubricating grease to the threads of the attach-
ment screws. After changing the sealing cap, use the Al-
len key to screw the attachment plate of the quick clamp
system back on.
Replacing the sealing rings (quad ring or spacer O-
ring) on models with Accumulator Change System
(ACS):
1. Use both hands to remove the damaged sealing rings.
Remove the quad ring carefully from the groove with-
out damaging it.
2. Place the new quad ring carefully in the groove. Slide
the spacer O-ring over the quad ring up to the rear
edge to the motor’s electronics.
Do not use sharp or pointed objects to remove or
install the sealing rings.
3. Spray the high-current contacts, the new sealing rings
(quad ring and spacer O-ring) and the sealing surface
of the sealing frame on the accumulator box ACS with
Klüber Kontasynth BA 100 special lubricant.
4. Reattach the accumulator box ACS to the SEABOB
housing as described in Chapter 5.3 "Installing the
accumulator box ACS".
a)
b)
c)
d)