| P
age 43
|
SEABOB
Operation
Manual
|
5
5.4.11 Displaying serial numbers
1. The SEABOB is in Sleep mode. The display is switched
off.
2. Tap the blue button.
3. The display is switched on, and the SEABOB logo ap-
pears.
4. Pull the Powergrip against the Controlgrip (within
3 seconds), and hold it there continously.
5. The software version number under the SEABOB logo
disappears after 1 second.
6. Hold the Powergrip in pulled position. Tap the green
button. The serial number of the SEABOB is displayed
(the first letter is an "S").
7. Hold the Powergrip in pulled position. Tap the red
button. The serial number of the accumulator box is
displayed (the first letter is an "A").
5.4.12 Entering PIN (Owner-PIN / User-
PIN)
Owner-PIN:
This PIN (Personal Identification Number) of the owner is
used to change the settings in the menu or to switch on
the device (if PIN prompt has been activated).
User-PIN:
This PIN (Personal Identification Number) of the user is
used to switch on the device (if PIN prompt has been
activated).
Note:
Please find your Owner-PIN on the supplied cer-
tificate.
The PIN prompt when switching on the device is deac-
tivated at the factory. This means that you will be able
to switch the SEABOB on without entering a PIN. If you
want to activate the PIN prompt when switching on the
device, or if you want to activate and change the User-
PIN, you will need the optional software available on CD
(see Chapter 11 "Accessories").
If the PIN prompt has been activated (PIN
�
"0000"), the
user will be required to enter the PIN when switching on
the device. To switch on the SEABOB, you can use either
the Owner-PIN or the User-PIN. Since you are the SEA-
BOB owner, you can use either PIN, so that you only have
to remember one number. The owner of the craft provides
the user only with the User-PIN for switching on the SEA-
BOB. The Owner-PIN is the only PIN that can be used for
safety settings, in particular the maximum diving depth,
maximum power and operating time limit (Timer).
Entering PIN