Never run the motor out of the water for longer
than approx. 10 seconds to discharge the accumu-
lator box. The seals of the motor and the hard-coated
motor shaft are designed exclusively for use in the water.
Operation out of the water leads to overheating due to
the lack of water to cool the device, thereby causing ir-
reparable damage to the seals and motor shaft.
Note:
If the charger is disconnected from the device
when programmed to partial charging, the SEABOB
switches to Off mode after 1 minute (system check). The
SEABOB can only be switched back on from Off mode
using a connected and active charger.
After transporting the device, charge the accumulator
box immediately (within 1 week) either for operation of
the craft or for storage by means of trickle-charge (the
charger remains connected; the aircraft symbol appears
in the display).
When transporting Li-Ion accumulators, always observe
the applicable safety regulations and the specific regu-
lations of the carrier. Be aware that safety regulations
can change from time to time. For up-to-date informa-
tion, please contact the manufacturer or your specialist
dealer.
Never expose the SEABOB, the accumulator box
and the charger to high temperatures (max. 60 °C /
140 °F) caused e.g. by open fire, direct sunlight or by stor-
age inside a closed motor vehicle or boot. If exposed to
heat, flaming gases can be discharged through the ac-
cumulator cells‘ safety valve causing serious injury. In ad-
dition, the LCD display will turn black if exposed to heat
and may become irreparably damaged.
Protect the charger, in particular the charging
plug with sealing cap and mains plug as well as
the charging socket on the accumulator box from dam-
age, dirt, dust, moisture and heat. Not doing so may re-
sult in electric shock!
5.14 Switching off the SEABOB for stor-
age or transport
Switch on the SEABOB (see Chapter 5.4.6 "Sleep mode").
Before completely switching off to Off mode, make sure
that the correct charge state for transport or the mini-
mum charge state required for storage (charge state "air
transport / storage") is reached.
Therefore, proceed as described in Chapter 5.12 "Stor-
ing the SEABOB and accumulator box ACS" and Chapter
5.13 "Air transport / transport of the SEABOB and ac-
cumulator box ACS".
If you disconnect the charger (after partial charging to the
charge state "air transport / storage"), the SEABOB will
switch off completely (switch to Off mode) after 1 minute
(system check), regardless of the current charge state.
After this occurs, the SEABOB can only be switched back
on using a connected and active charger.
Note:
Always keep in mind, particularly if you plan to
operate the craft, that you will need an active charger
connected to the mains voltage to switch the SEABOB
back on from Off mode.