CONTROL MODULE CAPABILITIES
Input Requirements
The Control Module accepts 12-24V AC/DC. System and Keypad current draw (max) is as
follows:
Standby: 50mA
During Operation: 150mA
Output Capabilities
Main Relay
The Main Relay will activate either a Fail-Safe or a Fail-Secure (Non Fail-Safe) electronic
locking device or other equipment. It may also be configured as a dry contact relay output to
control a gate operator or garage door opener. The main output is programmable from 01 to
99 seconds with optional timed or manual latching.
Output A
A relay contact output that can be programmed for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed Output (1 to 99 seconds).
2. Auxiliary Output - Manual Control or Timed Output (1 to 99 seconds).
3. Second Door - Users can be assigned to open a 2nd door.
4. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included).
Output B
A relay contact output that can be programmed for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed Output (1 to 99 seconds).
2. Auxiliary Output - Manual Control or Timed Output (1 to 99 seconds).
3. Third Door - Users can be assigned to open a 3rd door.
4. Internal Alarm System - Detect Break-in, Door-ajar & Tamper.
5. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included).