Red LED
Green LED
Slow Flash
Solid
P:\INSTALLATION INST\Access Control\INST-936.vsd 0106 Page 18
Programming Individual Users with the Keypad
Authorized users (master code or any user authorized to program) can program users
directly from the Keypad. Each Individual User can be assigned various authorizations.
Review System Setup before programming individual users.
To enter User Programming mode
:
Enter
* 1
Enter the Master Code (Default: 123) followed by
#
Example:
* 1 1 2 3 #
Proceed to one of the following seven programming options:
Keypad Status After Step Completion
Step
Beep
Red LED
Green LED
A
Double Slow Flash
Slow Flash
B-E
Double Slow Flash
Fast Flash
F
Triple Slow Flash
Slow Flash
NOTES:
1. Auxiliary Device or 2nd or 3rd Door authorization depends on configuration of the A and B Outputs. See Control Module
Setup on pages 15-16.
2. If either Output is configured for 2nd or 3rd Door operation and a user is given 4# or 6# Authorization, their User Code will
activate the configured output, not the Main Relay.
3. 24 Hour Access requires an external time clock or keyswitch. This allows you to restrict access to Users who are not
assigned 24-hour Access. See Time Clock Input on page 3.
1.)
Adding a New User
A. Enter
1 #
B. Enter the User ID (1 to 499) followed by
#
C. Enter the User Code/PIN (3-8 digits), followed by
#
D. Enter the desired User Authorization Code (see below), followed by
#
(Repeat for additional
authorizations or skip to Step E for no authorizations.)
Code User Authorization
1
Latching Authorization
2
Program or Delete Users Authorization
3
Output A Authorization (see notes)
4
2nd Door (see notes)
5
Output B Authorization (see notes)
6
3rd Door (see notes)
7
24-hour Access (see notes)
E. Once all desired User Authorizations have been assigned, enter # to complete programming for this
User.
F. To program an additional User, return to Step B.
G. If no more Users are to be added, enter
* *
to select another programming option (1-7), or if you have
completed all User Programming, enter
* *
a second time to complete programming sequence and reset
system to normal operation.
NOTE:
Once an authorized user enters programming mode, any combination of adding, modifying or deleting Users can