HARDWARE SETUP
VOLTAGE SELECTION
The factory default setting for the Keypad voltage is 12-24VDC. Verify that the jumper is
removed or placed over only one pin. If changing the voltage is necessary, make sure the
power is removed first.
KEYPAD OUTPUT SELECTION
Once the voltage jumper is verified or correctly set:
1. Remove power.
2. Jumper the two pins above the connector labeled “CONFIG”.
3. Apply appropriate power. (You should hear 4 beeps and the RED LED will flash and the
GREEN LED will be solid).
4. Now that the Keypad is in configuration mode, enter 98 followed by #. You should hear 3
beeps indicating successful configuration (the RED LED will continue to flash and the
GREEN LED will be solid). If you hear a long error beep, reenter 98 followed by #. To change
the audible beep or illumination, proceed as follows. Otherwise, go to step 5.
a. To change the audible beep, enter
Code Audible Beep
201 # Normal Beep (factory default)
200 # Short Click (quieter)
b. To change the illumination on the KP-31Y only, enter the code as follows:
Code Standby Mode
Normal Operation
210 # Off (factory default)
Off (factory default)
211 # Off
Dim
212 # Off
Bright
213 # Dim
Dim
214 # Dim
Bright
5. Remove power.
6. Remove configuration jumper.
7. Re-apply power.
8. Press the PROGRAM button in the Control Module to establish the encoded connection.
This will put the system into setup mode.
9. Press * * to exit.
NOTE
: If the configuration jumper is not removed, the LED's will flash and the
Keypad will beep continuously.
IMPORTANT:
Perform steps 1 through 9 below before configuring the control module
or programming users.