![SCI MM-380A Operation Manual Download Page 90](http://html1.mh-extra.com/html/sci/mm-380a/mm-380a_operation-manual_1217109090.webp)
MM-380A
13. Error List
13-1
13. Error List
The
MM-380A
informs of an error occurrence by showing the error number.
Error
code
Description
Cause
Remedy
E01
System error
Problem
detected in
MM-380A
’s
control system
Turn off the power and on again.
If "E01" (system error) appears again, the
MM-380A
needs repair. Please contact
Miyachi Corporation.
E02
Condition
memory error
Condition data in
memory is
damaged
Check all the settings.
If the data in memory is damaged, the
following are possible causes:
Generation of powerful power supply or
electrostatic noise
Abnormal supply voltage resulting, for
example, from lightening or induced
lightening
Flash memory’s rewrite limit exceeded
It would be useful to record the settings in
preparation for data damage. To print the
settings, refer to “n. PRINT Screen” in
Chapter 8 Operation Screens.
When you switch ON the power switch
while holding down the MENU key, a
message “Initializing --- Please wait a
moment.” appears, after which the memory
is initialized, resetting all settings back to
factory settings. Set the data you recorded
again. The memory will be initialized in
approximately 10 seconds. Do not turn
OFF the power during the initialization.
If "E02" (condition memory error) appears
again, the
MM-380A
needs repair. Please
contact Miyachi Corporation.
E03 Measured
value memory
error
Measured value
data in memory
is corrupt.
Measured value data in memory is corrupt.
If the data in memory is corrupt, the
following are possible causes:
Generation of power supply noise, or
electrostatic noise
Abnormal supply voltage resulting, for
example, from lightening or induced
lightening
Low memory battery voltage
It is advisable to back-up measured value
data onto other media often, as a
precaution against possible data
corruption.
If "E03" (Measured value memory error)
appears again, the
MM-380A
needs
repair. Please contact Miyachi Corporation.
E04
Memory
battery low
error
The backup
battery voltage is
2.2V or less.
Replace the batteries.