Page
10
of 24
F
OR THE
SEL-351 R
ELAY
Date
R
ELAY
S
ETTINGS
(S
ERIAL
P
ORT
C
OMMAND
SET
AND
F
RONT
P
ANEL
)
Date Code 20001006
Level 2 pickup (OFF, 40.10 - 65.00 Hz)
81D2P =
Level 2 time delay (2.00 - 16000.00 cycles in 0.25-cycle steps)
81D2D =
Level 3 pickup (OFF, 40.10 - 65.00 Hz)
81D3P =
Level 3 time delay (2.00 - 16000.00 cycles in 0.25-cycle steps)
81D3D =
Level 4 pickup (OFF, 40.10 - 65.00 Hz)
81D4P =
Level 4 time delay (2.00 - 16000.00 cycles in 0.25-cycle steps)
81D4D =
Level 5 pickup (OFF, 40.10 - 65.00 Hz)
81D5P =
Level 5 time delay (2.00 - 16000.00 cycles in 0.25-cycle steps)
81D5D =
Level 6 pickup (OFF, 40.10 - 65.00 Hz)
81D6P =
Level 6 time delay (2.00 - 16000.00 cycles in 0.25-cycle steps)
81D6D =
Reclosing Relay (See Tables 6.2 and 6.3)
(Make the following settings if preceding enable setting E79 = 1 - 4)
Open interval 1 time (0.00 - 999999.00 cycles in 0.25-cycle steps)
79OI1 =
Open interval 2 time (0.00 - 999999.00 cycles in 0.25-cycle steps)
79OI2 =
Open interval 3 time (0.00 - 999999.00 cycles in 0.25-cycle steps)
79OI3 =
Open interval 4 time (0.00 - 999999.00 cycles in 0.25-cycle steps)
79OI4 =
Reset time from reclose cycle (0.00 - 999999.00 cycles in 0.25-cycle steps)
79RSD =
Reset time from lockout (0.00 - 999999.00 cycles in 0.25-cycle steps)
79RSLD =
Reclose supervision time limit (OFF, 0.00 - 999999.00 cycles in 0.25-cycle
steps) (set 79CLSD = 0.00 for most applications; see Figure 6.2)
79CLSD =
Switch-Onto-Fault (See Figure 5.3)
(Make the following settings if preceding enable setting ESOTF = Y)
Close enable time delay (OFF, 0.00 - 16000.00 cycles in 0.25-cycle steps)
CLOEND =
52 A enable time delay (OFF, 0.00 - 16000.00 cycles in 0.25-cycle steps)
52AEND =
SOTF duration (0.50 - 16000.00 cycles in 0.25-cycle steps)
SOTFD =
POTT Trip Scheme Settings (Also Used in DCUB Trip Schemes) (See Figure 5.6)
(Make the following settings if preceding enable setting ECOMM = POTT, DCUB1, or DCUB2)
Zone (level) 3 reverse block time delay (0.00 - 16000.00 cycles in 0.25-cycle
steps)
Z3RBD =
Echo block time delay (OFF, 0.00 - 16000.00 cycles in 0.25-cycle steps)
EBLKD =
Echo time delay pickup (OFF, 0.00 - 16000.00 cycles in 0.25-cycle steps)
ETDPU =
Echo duration time delay (0.00 - 16000.00 cycles in 0.25-cycle steps)
EDURD =
Weak-infeed enable (Y, N)
EWFC =
Additional DCUB Trip Scheme Settings (See Figure 5.10)
(Make the following settings if preceding enable setting ECOMM = DCUB1 or DCUB2)
Guard present security time delay (0.00 - 16000.00 cycles in 0.25-cycle steps)
GARD1D =
Summary of Contents for SEL-351
Page 14: ...Courtesy of NationalSwitchgear com ...
Page 16: ...Courtesy of NationalSwitchgear com ...
Page 40: ...Courtesy of NationalSwitchgear com ...
Page 74: ...Courtesy of NationalSwitchgear com ...
Page 146: ...Courtesy of NationalSwitchgear com ...
Page 186: ...Courtesy of NationalSwitchgear com ...
Page 220: ...Courtesy of NationalSwitchgear com ...
Page 304: ...Courtesy of NationalSwitchgear com ...
Page 340: ...Courtesy of NationalSwitchgear com ...
Page 380: ...Courtesy of NationalSwitchgear com ...
Page 450: ...Courtesy of NationalSwitchgear com ...
Page 506: ...Courtesy of NationalSwitchgear com ...
Page 528: ...Courtesy of NationalSwitchgear com ...
Page 534: ...Courtesy of NationalSwitchgear com ...
Page 536: ...Courtesy of NationalSwitchgear com ...
Page 550: ...Courtesy of NationalSwitchgear com ...
Page 562: ...Courtesy of NationalSwitchgear com ...
Page 570: ...Courtesy of NationalSwitchgear com ...
Page 584: ...Courtesy of NationalSwitchgear com ...
Page 602: ...Courtesy of NationalSwitchgear com ...