Product Description
EN
· 30.30.01.02851 · 01 · 03/22
21 / 96
3.4.6
Ejector on Grippers FXP-i
CAUTION
Noise pollution due to the escape of compressed air and exhaust air
Hearing damage!
Wear ear protectors.
The area gripper must only be operated with a silencer.
The plug-in ejector has a lightweight design and is easy to replace. It is equipped with 1–4 ejector chains depending on
the size to enable optimum performance adjustment. The connection is designed for an 12/9 hose. For lengths longer
than 2 m, a hose with a larger internal diameter must be selected. The flowing compressed air pressure directly in
front of the ejector must not exceed or fall below the values listed in the technical data. We recommend monitoring
the pressure using a pressure gauge.
3.4.7
Hose Connector on Grippers FMP-i
NOTE
Closing the ventilation opening (2)
Increase in the internal pressure in the valve
Do not close the ventilation opening (filter). When the ventilation opening/exhaust air outlet opening
is closed, the valve may malfunction or become damaged and there is a risk of injury.
1
Vacuum hose connection
2
Ventilation opening
The vacuum supply from the vacuum generator installed by the customer is applied through a vacuum hose. The hose
is connected using the hose connector.
3.4.8
Valve for Grippers FMP-i
The valve is available in two sizes. The smaller version is designed for an internal hose diameter of 32 mm, the larger
version for 60 mm. The connection is designed for an 12/9 hose. For lengths longer than 2 m, a hose with a larger
internal diameter may need to be selected. The flowing compressed air pressure directly in front of the valve must not
exceed or fall below the values listed in the technical data. We recommend monitoring the pressure using a pressure
gauge.