Appendix
92 / 96
EN
· 30.30.01.02851 · 01 · 03/22
lock (lock menu editing)
Bit 3
–15: reserved
90
0x005A
0
nFc
Extended
Device Access
Locks
1 byte
rw
0
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
Bit 3: local user interface
locked (manual mode locked)
Bit 4: IO-Link event lock
(suppress sending IO-Link
events)
Bit 5
–7: Not used
77
0x004D
0
Pin
Menu PIN code
2 bytes
0
–999
rw
0
0 = Menu editing unlocked
>0 = Menu editing locked with
pin-code
91
0x005B
0
NFC PIN code
2 bytes
0
–999
rw
0
PIN for writing data from NFC
app
Initial Settings
69
0x0045
0
bLo
Blow-off mode
1 byte
0
–2
rw
0
0 = Externally controlled blow-
off (-E-)
1 = Internally controlled blow-
off
– time-dependent (I-t)
2 = Externally controlled blow-
off
– time-dependent (E-t)
71
0x0047
0
Ou2
Output 2
function
1 byte
0
–1
rw
0
0 = NO
1 = NC
73
0x0049
0
P-n
Signal Type
1 byte
0
–1
rw
0
0 = PNP
1 = NPN
74
0x004A
0
uni
Display Unit
1 byte
0
–3
rw
0
0 = mbar
1 = kPa
2 = inHg
3 = psi
75
0x004B
0
dLY
Output filter
2 bytes
0
–999
rw
10
Unit: 1 ms
76
0x004C
0
Eco
Eco mode
1 byte
0
–2
rw
0
0 = off
1 = on (full eco mode with
display switching off
completely)
2 = Lo (medium eco mode with
display dimmed to 50%)
79
0x004F
0
dIS
Display rotation
1 byte
0
–1
rw
0
0 = Standard
1 = Rotated
Process Settings
275
0x0113
P-n
Number of
active profile
1 byte
ro
Number of the active profile:
0
–3
Production Setup - Profile P0
68
0x0044
0
Ctr
Air saving
function
1 byte
0
–2
rw
1
0 = not active (off)
1 = active (on)
2 = active with supervision
(onS)
78
0x004E
0
dCS
Disable
continuous
suction
1 byte
0
–1
rw
0
0 = off
1 = on
100
0x0064
0
SP1
Switch Point 1
2 bytes
999 > SP1 >
rP1
rw
750
Unit: 1 mbar
101
0x0065
0
rP1
Reset Point 1
2 bytes
SP1 > rP1 >
SP2
rw
600
Unit: 1 mbar
102
0x0066
0
SP2
Switch Point 2
2 bytes
rP1 > SP2 >
rP2
rw
550
Unit: 1 mbar
103
0x0067
0
rP2
Reset Point 2
2 bytes
SP2 > rP2 >=
10
rw
540
Unit: 1 mbar
106
0x006A
0
tbl
Duration
automatic blow
2 bytes
10
–9999
rw
200
Unit: 1 ms
107
0x006B
0
t-1
Permissible
evacuation time
2 bytes
0
–9999
rw
2000
Unit: 1 ms. No t-1 Warning if
set to 0
108
0x006C
0
-L-
Permissible
leakage rate
2 bytes
0
–999
rw
250
Unit: 1 mbar/sec. No -L-
Warning if set to 0
119
0x0077
0
Profile name
1 to 32
bytes
rw
***
Production Setup - Profile P1
180
0x00B4
0
Air saving
function
1 byte
0
–2
rw
1
Profile P-1
(selected by PD Out 0 -
Profile-Set = 1)
181
0x00B5
0
Disable
continuous
suction
1 byte
0
–1
rw
0
182
0x00B6
0
Switch Point 1
2 bytes
999 > SP1 >
rP1
rw
750
183
0x00B7
0
Reset Point 1
2 bytes
SP1 > rP1 >
SP2
rw
600
184
0x00B8
0
Switch Point 2
2 bytes
rP1 > SP2 >
rP2
rw
550
185
0x00B9
0
Reset Point 2
2 bytes
SP2 > rP2 >=
10
rw
540
186
0x00BA
0
Duration
automatic blow
2 bytes
10
–9999
rw
200
187
0x00BB
0
Permissible
evacuation time
2 bytes
0
–9999
rw
2000
188
0x00BC
0
Permissible
leakage rate
2 bytes
0
–999
rw
250
199
0x00C7
0
Profile name
1 to 32
bytes
rw
***
Production Setup - Profile P2
200
0x00C8
0
Air saving
function
1 byte
0
–2
rw
1