BASCSOUL_EN
V02 | 10.2017
23
Installation and commissioning
4.1.2
Ambient conditions
If the coffee machine was exposed to subzero temperatures:
► Contact customer service before commissioning.
4.2
Power supply
4.2.1
Conditions
The equipment must be connected in accordance with the regulations of the country in which it is installed. The volt-
age specified on the serial plate must match the mains voltage at the installation location.
4.2.2
Power cable
NOTE
Risk of machine damage! The location where the coffee machine is installed must
satisfy the ambient conditions specified below. If they are not satisfied, the coffee
machine may become damaged.
The following conditions absolutely must be met:
• Ambient temperature of 10 °C to 40 °C (50 °F to 104 °F)
• Relative humidity of max. 80% RH
• This coffee machine is designed for indoor use only. Do not use in the open and never
expose to the weather (rain, snow, subzero temperatures).
DANGER
Risk of electrocution! An imminently dangerous situation that may result in death
or serious injury from electric shock.
Please adhere to the following points:
• The phase must be fused at the ampere value specified on the serial plate.
• It must be possible to disconnect the device from the mains power supply at all poles.
• The electrical system on the installation site must conform to IEC 364 (DIN VDE 0100).
To increase safety, the device should be connected to a ground fault circuit interrupter
with 30 mA nominal error current (EN 61008). (Type B residual current circuit breakers
ensure response even in the event of smooth DC residual currents. This results in a
high level of safety.)
• Never operate a device with a damaged power cable. Have a defective power cable or
plug replaced immediately by a qualified service technician.
• Schaerer AG does not recommend using an extension cord. If an extension cord is
used despite this (minimum cross-section: 1.5 mm²), please comply with the manufac-
turer’s specifications for the cable (operating instructions) and with applicable local re-
gulations.
• Route the power cable in such a way that it does not pose a tripping hazard. Do not pull
the cable over corners or sharp edges, pinch it between objects or allow it to hang loo-
sely in open spaces. Do not position the cable over hot objects, and protect the cable
from exposure to oil and aggressive cleaning products.
• Never lift or pull the device by the power cable. Never pull the plug out of the socket by
its cable. Never touch the power cable or plug with wet hands. Never insert a wet plug
into a power socket.
DANGER
User at risk! Use of a faulty power cable or one that is not the original cable results
in the risk of electric shock and fire. Use the original power cable.
The measures described for preventing this danger must be adhered to:
• The original power cable for your country can be obtained from your service partner.
• Power cables that are plugged in on both sides can be replaced by the customer.
• Permanently connected power cables must be replaced by a service technician.