BASCSOUL_EN
V02 | 10.2017
109
Troubleshooting
Refilling the beans
(Centre grinder empty)
The centre bean hopper is
empty.
► Refill bean hopper.
Refilling the beans
(Right grinder empty)
The right bean hopper is
empty.
► Refill bean hopper.
Inserting ground coffee
into manual inlet
The right bean hopper is
empty.
► Open the manual inlet cover in the centre
bean hopper.
► Fill ground coffee.
► Close cover to the manual inlet.
Hot water boiler excess
temperature
The water supply has been
interrupted.
► Ext. level. Check the drinking water tank (op-
tion) or the condition of the mains water sup-
ply.
The machine has overheat-
ed.
► Disconnect the machine from the power sup-
ply and let it cool off.
The SSR is defective.
► Contact your service partner.
The Klixon has triggered.
Steam boiler excess tem-
perature
The water supply has been
interrupted.
► Ext. level. Check the drinking water tank (op-
tion) or the condition of the mains water sup-
ply.
Blockage in the steam sys-
tem
► Check and clean the beverage outlet and
steam system.
The machine has overheat-
ed.
► Disconnect the machine from the power sup-
ply and let it cool off.
The SSR is defective.
► Contact your service partner.
The Klixon has triggered.
Hot water temperature too
low
Steam boiler temperature
too low
Heating phase
► Wait for the machine to heat up completely.
Error while heating
► Disconnect the machine from the power sup-
ply.
► Connect the machine again and switch it on.
Hot water boiler heating
time out
Steam boiler heating time
out
Although the heating is
switched on, the set tempera-
ture was not reached within 5
minutes.
► Contact your service partner.
NTC hot water boiler short
NTC steam boiler short
The main board does not de-
tect a resistance. A maximum
temperature (approx. 150°C)
is measured.
Beverage dispensing is disa-
bled.
► Contact your service partner.
NTC hot water boiler open
NTC steam boiler open
The temperature sensor has
been interrupted. A minimum
temperature is measured.
► Contact your service partner.
Brewing unit excess cur-
rent
Excess current was detected
on the brewing unit motor.
► Contact your service partner.
Co
de
Display message
Cause
What to do