![ScentAir ScentStream SXD2110 Installation And Operation Instructions Manual Download Page 6](http://html1.mh-extra.com/html/scentair/scentstream-sxd2110/scentstream-sxd2110_installation-and-operation-instructions-manual_1209373006.webp)
6
PART#-31600035-LIT-SXD2110-MANUAL-REV.A
Duct Assembly Mounting Procedure
1. Determine the location on the air handler or supply duct where the Duct Input Assembly
will be mounted - Be sure to consider all criteria:
•
The collector & bottle assembly will need to be mounted within 8ft./2.4m of the
duct input assembly insertion point.
•
Determine which supply duct will be used for scent.
•
Determine an entry point on the bottom (preferably) or the side of the duct.
•
Make sure that the collector & bottle assembly can be mounted lower than the
chosen entry point in the duct.
•
Choose an insertion point downstream of fire protection devices and heat strips.
•
Keep as much distance as possible from louvered vents.
2. Mount the Duct Input Assembly with coverplate onto air handler
•
Drill a 1in./2.5cm hole in duct.
•
If necessary, use a screwdriver to punch through the insulation inside of the duct.
•
At the insertion point on the duct, the duct input assembly will attach to the duct
with the shorter end on the outside and the longer end positioned in the airstream
of the duct.
•
Insert the duct input assembly pointing in the direction of airflow. Be sure the duct
input assembly is through the insulation and in the main air stream of the duct.
*Ensure that the duct input assembly will always be ascending at least slightly and
never pointing downwards.
•
Make sure foam seal is in place on the duct side of the plate to prevent air leaks
•
Attach output nozzle assembly using 4 self tapping sheet metal screws.
Collector & Bottle Mounting Procedure
1. Mount the Collector & Bottle Assembly:
•
Determine the location where shelf will be mounted on wall.
•
Not to exceed 8ft./2.4m from where scent is injected into the duct.
NOTE: The collector & bottle assembly must be mounted below the entry point into the
duct so that the scent delivery tube can ascend in a constant climb with no dips or sharp
bends. This allows for any residual oil that might collect on the inside wall of the scent
delivery hose to drain back into the collector assembly.
•
Attach the shelf to the wall or air handler using appropriate hardware.
FIG. D
Plastic Wall Anchor
Small Flat Washer
1-1/4” Wood Screw
2. Attach the Collector to the Bottle:
•
Place the fragrance bottle on the shelf, and verify that it is stable.
•
Make sure the white bottle seal is in place in the underside of the collector and
screw the collector assembly to the top of the bottle.
•
Carefully tighten the Collector to the Bottle making sure there is a good air-tight
seal.
FIG. E
FIG. D