PROGRAMMED EVENTS

Use the 

Event

 menu to schedule programmed events to operate the system during specific 

hours. You may program up to 14 events each of which can be set to occur on multiple days 
of the week. Events can be added, deleted, reviewed, and changed from this menu.

• 

Press any button to activate the screen if the backlight is off.

• 

Press MODE once from the main screen to navigate to the 

Set Event

 screen, the words 

Set

” and “

Event

” will be shown on the screen. The selected event number will always 

be shown in this mode. Upon entering 

Set Event

, the event number will be showing an 

‘empty’ event with dashes displayed for the time. 

• 

Press SELECT to begin editing 

Event 1

. The days of the week will begin to blink.

• 

Press UP / DOWN to change to the desired day(s) for the event to take place. 
Continuing to press UP / DOWN will show various combinations of days, there are 17 
options, including 7 for the individual days (Press UP first) and 10 other combinations 
(Press DOWN first). The default with all days flashing would create an event that is 
active every day of the week.

• 

Press NEXT to navigate to each of the four digits of the 

On Time

, the words “

Set

” and 

On

” will be shown on the screen. Press UP / DOWN to set the desired 

On Time

. This 

will be when the system will start to produce fragrance for this event.

• 

Press NEXT to navigate to each of the four digits of the 

Off Time

, the words “

Set

” and 

Off

” will be shown on the screen. Press UP / DOWN to set the desired 

Off time

. This 

is the time that the system will end operation for this event. 

NOTE: If the Off Time is earlier than the On Time the machine will understand that the 
event will run past midnight and turn off the next day.

• 

Press NEXT to navigate to the 

Scent Intensity

 screen for Event 1. Press PREVIOUS 

/ NEXT to go back and forth between any of the settings for the current event. More 
information on 

Scent Intensity

 can be found on the next page.

• 

Press SELECT to accept all current event settings and return to the Main screen. The 
display screen backlight will blink to indicate the event was saved OR display “

Error

” if 

there was a problem with the event times.

• 

Press MODE at any point before pressing SELECT to discard the current changes and 
return to the review of existing events.

NOTE: If error was displayed the system will remain in edit mode so the current event 
can be corrected without losing any of the information already entered.
NOTE: After saving an event the system will automatically display the next empty event 
number, so multiple new events can be added one after another with minimum effort.

GLOSSY

CLEAR

WINDOW

GLOSSY

CLEAR

WINDOW

GLOSSY

CLEAR

WINDOW

GLOSSY

CLEAR

WINDOW

Summary of Contents for ScentStream SXD2110

Page 1: ...ScentStream SXD2110 SCENT DELIVERY SYSTEM Installation and Operation Instructions...

Page 2: ...peration 16 Fragrance Changeover Instructions 17 Troubleshooting 19 REQUIRED TOOLS 5 32 Masonry Drill Bit 1 2 Drill Bit 1 4 Drill Bit 1 or 2 5cm Hole Saw Drill Roto Hammer Pencil Tape Measure Small Le...

Page 3: ...s such that the property is properly heated and cooled it will then evenly distribute the scent to the same area Identifying which air handlers service the target area is required for proper installat...

Page 4: ...bracket 2 Determine mounting location Consider all criteria when selecting the location The control unit should be mounted within 10 ft 3 1m of a AC outlet The control unit should be within 25 ft 7 6...

Page 5: ...n the side of the unit Then pull back slightly to check that the tubing is locked in place To remove the tubing from these quick disconnect fittings just push the collar of the fitting down and pull t...

Page 6: ...nput assembly is through the insulation and in the main air stream of the duct Ensure that the duct input assembly will always be ascending at least slightly and never pointing downwards Make sure foa...

Page 7: ...h and attach to the barbed fitting on the collector NOTE Make sure that the tubing descends gradually to the collector Flat areas or catches will cause the system to build up excess oil in the tubing...

Page 8: ...saved LCD Display Pressing any button will turn the backlight on and activate the screen The backlight must be on in order to perform any of the operations described in this manual If left alone for t...

Page 9: ...T EDIT SELECTED EVENT M T W Th F S Su SCENT CYCLE TIME SCENT LEVEL MAIN SCREEN ADJUST CURRENT EVENT SCENT OPTIONS 24 HOUR CLOCK MONTH DAY YEAR PUMP SPEED ADJUST 1 2 DST ON OFF DATE FORWARD DATE BACKWA...

Page 10: ...if the backlight is off Press MENU four 4 times from the main screen the words Set and DST will be displayed along with the current DST setting either OFF if the feature is turned off or ON and the da...

Page 11: ...set the desired On Time This will be when the system will start to produce fragrance for this event Press NEXT to navigate to each of the four digits of the Off Time the words Set and Off will be sho...

Page 12: ...in an environment where customers might stay for longer periods by counteracting the natural tendency to become used to a scent over time SHORT Scent Time Setting shorter scent times is best used to...

Page 13: ...umber is always empty Press SELECT to edit the currently selected event This will cause one of the fields to blink and allow you to make any changes desired Use PREVIOUS NEXT to switch between all of...

Page 14: ...efine the scent levels for the overlap The display screen backlight will display Error if there was a problem with the event times If error was displayed the system will remain in edit mode so the cur...

Page 15: ...digit of 0 9 Press SELECT to save the lockcode to the system NOTE Once a lockcode is set to ON the machine will be automatically locked two 2 minutes after any authorized operation When lockcode is di...

Page 16: ...edit the current scent settings displayed with the Scent Time blinking Press SELECT to save any changes or MODE to exit without saving While the machine is in auto mode the changes will only work for...

Page 17: ...ew and remove the collector from the bottle of old fragrance oil being careful to catch any drips with the paper towels If the bottle was relatively full pause with the tubes at the bottom of the coll...

Page 18: ...s write down the current setting and adjust it upwards to at least 3 minutes Record the current OFF time setting and adjust it downwards to 10 seconds This will make the pump run most of the time 22 R...

Page 19: ...es reduction enlargement turn split etc If both the fan is on and the pressure switch probe is located in the correct position check the switch by blowing into the probe If the switch clicks there may...

Page 20: ...For further assistance please contact Technical Services at 704 504 2320 techservices scentair com...

Reviews: