FRAGRANCE CHANGEOVER INSTRUCTIONS
The following procedure should be followed whenever a ScentStream™ system is to be
changed from one fragrance to another in order to minimize any undesirable mixing of the
two scents.
Materials needed:
•
One bottle (5L) of new fragrance sealed with screw cap
•
One bottle partially filled (200ml) with clear cleanout liquid (DPG) from ScentAir
(never use water) also sealed with screw cap
•
Paper towels
These instructions are written so that the collectors can be in their as installed location during
the cleanout process. If the duct insertion points or mounting locations need to be changed
as well please refer to the installation guides for the ScentStream™ for detailed instructions.
It is recommended to have the ScentStream™ machines switched off for a few hours before
doing the change out. In any case allow at least 20 seconds after switching machine off
before removing the collector from the bottle.
1. Disconnect the 12V power supply from the ScentStream™ pump unit to ensure that it is
switched off during the bottle change. DO NOT change any of the controls at this time.
2. At the first collector associated with the system, disconnect the air in tubing from the
Quick Disconnect Fitting on the top of the collector by pressing in on the collar while
pulling the tube straight out upwards.
3. Now remove the fragrance output tube by depressing the metal release on the plastic
fitting and pulling the tube attached to the metal coupler straight up. Once removed
use a paper towel to catch any drips from the bottom of the fragrance tube.
4. Unscrew and remove the collector from the bottle of old fragrance oil, being careful
to catch any drips with the paper towels. If the bottle was relatively full pause with the
tubes at the bottom of the collector above the surface of the liquid to drain for a few
moments before removing from the bottle completely.
5. Temporarily set the collector down on its side on a clean surface, do not touch or allow
the white tubing at the collector bottom to contact any surface, it must stay clean.
6. Take down the bottle of used fragrance oil and put the bottle of cleanout liquid in its
place.
7. Screw the collector onto the cleanout liquid bottle firmly.
8. Re-attach the air supply tubing by pressing straight into the QD fitting.
9. Re-attach the fragrance output tubing by pressing straight into the fitting until it clicks.
IF THIS IS THE ONLY COLLECTOR REQUIRING A FRAGRANCE
CHANGE CONNECTED TO THIS SXD2110 PUMP UNIT
SKIP TO STEP 17
10. Take the used bottle of fragrance oil with you and proceed to the next collector attached
to the ScentStream™.
11. At the next collector associated with the ScentStream™ system disconnect the air in
tubing from the QD fitting on the top of the collector by pressing in on the collar while
pulling the tube straight out upwards.
12. Now remove the fragrance output tube by depressing the metal release on the plastic
fitting and pulling the tube attached to the metal coupler straight up. Once removed
use a paper towel to catch any drips from the bottom of the fragrance tube.
13. Unscrew and remove the collector from the bottle of old fragrance oil, being careful
to catch any drips with the paper towels. If the bottle was relatively full pause with the
tubes at the bottom of the collector above the surface of the liquid to drain for a few
moments before removing from the bottle completely.