Maximum Distance Between Assemblies
When installing the ScentStream™ there are three (3) basic assemblies which will be
permanently mounted to either a wall or the air duct. The system ships with 25ft./7.6m of
1/4IN. AIR SUPPLY TUBE to connect the CONTROL UNIT to the COLLECTOR & BOTTLE
ASSEMBLY, and 9ft./2.4m of 3/8IN. OUTPUT TUBE to connect the COLLECTOR & BOTTLE
ASSEMBLY to the DUCT INPUT ASSEMBLY. Please note these tube lengths and consider them
when mounting each assembly. The Collector Assembly incorporates a precision nozzle that
can be effected by dust or debris. Use care to protect the tubing and the COLLECTOR AND
BOTTLE ASSEMBLY from dust or debris.
AIR DUCT
CONTROL UNIT
1/4in. Tube
25ft. / 7.6m Length
OUTPUT TUBE
COLLECTOR &
BOTTLE ASSEMBLY
DUCT INPUT ASSEMBLY
Control Unit Mounting Procedures
1. Press the blue shock absorbent grommets into the large holes on the SXD2110 bracket.
2. Determine mounting location - Consider all criteria when selecting the location:
•
The control unit should be mounted within 10 ft./3.1m of a AC outlet.
•
The control unit should be within 25 ft./7.62m of the nozzle assembly to ensure
proper air pressure on the nozzle. For ease of installation and service, it is
recommended that this distance be as short as possible.
•
Mount in a clean, dry space 3-6 ft./0.9-1.8m from floor for easy access.
•
Avoid locations that will collect dust. Try to keep the ScentStream hoses and power
supply off the floor to avoid picking up excess dust and dirt.
3. Securing ScentStream Unit - Position pump on wall, mark hole locations and secure to
wall. The ScentStream can be mounted to a wall or other structure using the provided
drywall anchors and screws, or the Tapcon concrete screws.
FIG. A
NOTE: When mounting the control unit to the wall, ensure the top of the system is level
front to back and left to right.
Blue Shock Absorbent
Grommets
# 8 Plastic drywall anchor
3/8” Nylon Spacer
1-1/4” Sheet Metal Screw
Large Flat washers
FIG. A
3/8in. Tube
9ft. / 2.4m Length
AIR SUPPLY TUBE
CONTROL UNIT