14. Temporarily set the collector down on its side on a clean surface, do not touch or allow
the white tubing at the collector bottom to contact any surface, it must stay clean.
15. Transfer all the used oil into one of the used bottles, then screw the collector at this
location back onto an empty bottle
16. Re-attach both of the tubes to this collector by pressing them straight in until they seal.
17. If there are additional collectors attached to the same ScentStream™ repeat steps
10-16 until all the used oil has been gathered into one bottle and all the collectors are
attached to the system and in empty bottles.
18. Return to the ScentStream™ control unit. Note that all air supply tubes should be
attached to collectors so that the system can be pressurized.
19. If the optional duct sensor (with green connector) is plugged into the ScentStream™
near the power jack, unplug it now (2 small screws may be holding the connector in
place if it does not pull out easily).
20. Re-attach the DC power plug to the ScentStream™ control unit. If the machine is set to
timer or
ON
mode the pump will come on. If not remember the setting and move the
switch to
ON
now.
21. Using the set button check and record the
ON
and
OFF
cycle times for the machine, if
the
ON
time is less than 3 minutes write down the current setting and adjust it upwards
to at least 3 minutes. Record the current
OFF
time setting and adjust it downwards to
10 seconds. This will make the pump run most of the time.
22. Record the setting of the Nozzle mode switch and move it to the highest setting
23. Return to the first collector (with the cleanout liquid bottle).
24. Remove the fragrance output tube and verify (with a flashlight ) that atomized vapor is
exiting the top of the collector as pressure is suppled. If it is not, try tilting the bottle so
that the liquid level is higher under the collector.
25. Replace the output tube and allow it to atomize for at least 3 minutes.
26. Remove the tubing from the top of the collector.
27. Remove the collector from the cleanout bottle, allow it to drain for a minute or so
before installing the collector on top of the new fragrance bottle.
28. Reattach all tubing, and check that the fittings on the collector are properly finger tight,
and that the collector is firmly screwed onto the new bottle.
29. Take the Cleanout bottle with you to the next collector in the system and repeat steps
3-8 and 24-28 for each collector in turn.
30. Return to the ScentStream™ control unit and change all settings back to their original
values.
31. Reinstall the duct sensor connector if it was installed.
32. Unplug the power connector and replace it one last time.
33. All the collectors should be connected to new bottles of fragrance. Replace the bottle
caps on the empty bottles and collect tools before leaving.