ScentAir ScentStream SXD2110 Installation And Operation Instructions Manual Download Page 1

ScentStream™ SXD2110

SCENT DELIVERY SYSTEM 

Installation and Operation Instructions

Summary of Contents for ScentStream SXD2110

Page 1: ...ScentStream SXD2110 SCENT DELIVERY SYSTEM Installation and Operation Instructions...

Page 2: ...peration 16 Fragrance Changeover Instructions 17 Troubleshooting 19 REQUIRED TOOLS 5 32 Masonry Drill Bit 1 2 Drill Bit 1 4 Drill Bit 1 or 2 5cm Hole Saw Drill Roto Hammer Pencil Tape Measure Small Le...

Page 3: ...s such that the property is properly heated and cooled it will then evenly distribute the scent to the same area Identifying which air handlers service the target area is required for proper installat...

Page 4: ...bracket 2 Determine mounting location Consider all criteria when selecting the location The control unit should be mounted within 10 ft 3 1m of a AC outlet The control unit should be within 25 ft 7 6...

Page 5: ...n the side of the unit Then pull back slightly to check that the tubing is locked in place To remove the tubing from these quick disconnect fittings just push the collar of the fitting down and pull t...

Page 6: ...nput assembly is through the insulation and in the main air stream of the duct Ensure that the duct input assembly will always be ascending at least slightly and never pointing downwards Make sure foa...

Page 7: ...h and attach to the barbed fitting on the collector NOTE Make sure that the tubing descends gradually to the collector Flat areas or catches will cause the system to build up excess oil in the tubing...

Page 8: ...saved LCD Display Pressing any button will turn the backlight on and activate the screen The backlight must be on in order to perform any of the operations described in this manual If left alone for t...

Page 9: ...T EDIT SELECTED EVENT M T W Th F S Su SCENT CYCLE TIME SCENT LEVEL MAIN SCREEN ADJUST CURRENT EVENT SCENT OPTIONS 24 HOUR CLOCK MONTH DAY YEAR PUMP SPEED ADJUST 1 2 DST ON OFF DATE FORWARD DATE BACKWA...

Page 10: ...if the backlight is off Press MENU four 4 times from the main screen the words Set and DST will be displayed along with the current DST setting either OFF if the feature is turned off or ON and the da...

Page 11: ...set the desired On Time This will be when the system will start to produce fragrance for this event Press NEXT to navigate to each of the four digits of the Off Time the words Set and Off will be sho...

Page 12: ...in an environment where customers might stay for longer periods by counteracting the natural tendency to become used to a scent over time SHORT Scent Time Setting shorter scent times is best used to...

Page 13: ...umber is always empty Press SELECT to edit the currently selected event This will cause one of the fields to blink and allow you to make any changes desired Use PREVIOUS NEXT to switch between all of...

Page 14: ...efine the scent levels for the overlap The display screen backlight will display Error if there was a problem with the event times If error was displayed the system will remain in edit mode so the cur...

Page 15: ...digit of 0 9 Press SELECT to save the lockcode to the system NOTE Once a lockcode is set to ON the machine will be automatically locked two 2 minutes after any authorized operation When lockcode is di...

Page 16: ...edit the current scent settings displayed with the Scent Time blinking Press SELECT to save any changes or MODE to exit without saving While the machine is in auto mode the changes will only work for...

Page 17: ...ew and remove the collector from the bottle of old fragrance oil being careful to catch any drips with the paper towels If the bottle was relatively full pause with the tubes at the bottom of the coll...

Page 18: ...s write down the current setting and adjust it upwards to at least 3 minutes Record the current OFF time setting and adjust it downwards to 10 seconds This will make the pump run most of the time 22 R...

Page 19: ...es reduction enlargement turn split etc If both the fan is on and the pressure switch probe is located in the correct position check the switch by blowing into the probe If the switch clicks there may...

Page 20: ...For further assistance please contact Technical Services at 704 504 2320 techservices scentair com...

Reviews: