71
MPS4264
Section 5: Software
Miscellaneous Variables (LIST M)
This is a collection of settings that are used for debugging or other setting.
List Miscellaneous Settings (LIST M)
DESCRIPTION
Returns all of the miscellaneous settings
SYNTAX
LIST M
RETURNS
All of the miscellaneous setting followed by the prompt.
EXAMPLE
LIST M
SET SIM 0
SET ECHO 0
SET XITE 2 0 1
SET SVRSEL 1
>
Set Simulation (SIM)
DESCRIPTION
Sets debugging and simulation modes.
SYNTAX
SET SIM <code in hex>
Where <code in hex>:
Bit 2 when set shows PTP calculated start differentials
Bit 0 when set uses a prototype board
RETURNS
Prompt when ready to accept a new command
EXAMPLE
SET SIM 4
>
DEFAULT
0
RANGE
0 to 65535
Set Echo (ECHO)
DESCRIPTION
Sets echo for serial and Telnet communication.
SYNTAX
SET ECHO <0- no echo, 1-echo >
RETURNS
Prompt when ready to accept a new command
EXAMPLE
SET ECHO 1
>
DEFAULT
0
RANGE
0 or 1
Set Excitation (XITE)
DESCRIPTION
Sets excitation mode
SYNTAX
SET XITE <0-neg only, 1-pos only, 2-reg, 3-reversed polarity> <man A/D rate 0 for auto> <A/D Idle
enabled>
RETURNS
Prompt when ready to accept a new command
EXAMPLE
SET XITE 2 0 1
>
DEFAULT
2 0 1
RANGE
<0,1 or 2> <0 to 9 or F> <0, 1>
Summary of Contents for MPS4264
Page 1: ...MPS4264 Miniature Pressure Scanner Hardware and Software Manual Software Version 2 07...
Page 2: ......
Page 3: ......
Page 6: ...INTENTIONALLY LEFT BLANK...
Page 12: ...6 MPS4264 Section 1 Specifications INTENTIONALLY LEFT BLANK...
Page 18: ...12 MPS4264 Section 2 Introduction INTENTIONALLY LEFT BLANK...
Page 32: ...26 MPS4264 Section 4 Hardware INTENTIONALLY LEFT BLANK...
Page 38: ...32 MPS4264 Section 5 Software INTENTIONALLY LEFT BLANK...
Page 81: ...75 MPS4264 Section 6 Maintenance INTENTIONALLY LEFT BLANK...
Page 86: ...80 MPS4264 Section 6 Maintenance INTENTIONALLY LEFT BLANK...
Page 87: ...81 MPS4264 Appendix INTENTIONALLY LEFT BLANK...