Saia-Burgess Controls AG
Manual for PCD7.L79xN room controllers
│
Document 27 / 602
E
N02 │ 2013-11-27
Example applications
4-1
4
4
Example applications
4.1 General
The programming of the PCD7.L79xN product family presented here uses the Saia
PG5
®
FBox family "RoomControler PCD7_L79x". The library is supplied by SBC free
of charge, and can be obtained from Saia-Burgess Controls AG in Murten.
4.2
System requirements
■
Saia PCD1, PCD2, PCD3 or PCS1
■
Saia PG5
®
1.4 or higher
■
Application FBox library, HLK-Init, HeaVAC initialisation
■
Standard FBox library, communication, SASI master
■
User FBox library, RoomController PCD7_L79x
4.3 Initialisation
At start of project, the HeaVAC library and the serial interface need to be initialised.
The picture shows the configuration for a PCD3 using the integrated serial RS-485
interface «Channel 2».
Initializing for the communications room controller must also set the FBox «L79x Se-
tup» at the beginning of the program.