Page 24
OMEGA IPL Installation Guide
Part No. 000823, 06-m02-2012
Step 15
Install call stations
Install the call stations.
Procedure
1
Mount the call stations starting with the lowest landing.
An example of a call station is shown below.
2
When mounting the call station, be sure to allow
enough clearance for the carriage at the landings.
3
Mount the call station at a height of one meter (39
inches) from the floor to the center of the call station.
4
If mounting the call station on a post instead of
attaching it to the wall, ensure the post is plumb before
mounting.
5
Wire the call stations according to the Electrical
Schematics shipped with the lift.
Figure 64
Call station (for automatic platform)
Step 16
Route and connect electrical wiring
Route and connect all electrical wiring.
Procedure
1
Connect all electrical wiring in accordance with the
Electrical Schematics provided with the lift.
2
Set up a ground connection (if required).
3
Choose the most effective method of wiring for your
installation; no two systems are the same.
In general, the following electrical connections are
required:
• 1 cable for upper hall call landing station
• 1 cable for lower hall call landing station
• 1 cable for each intermediate hall call landing station
• 1 cable for lower normal limit switch
• 1 cable for each intermediate normal limit switch
• 1 cable for lower final limit switch and overspeed
switch
• 1 cable for upper normal limit switch and upper final
limit switch
• 1 cable for motor connections
• 1 cable for connection of the brush contact