Version 1.0
[
50
]
SAV 220.76 /SAV 242.92 /SAV 243.70 /.71 /
SAV 243.72 /.73 /.76 /.77 /.78 /.79 /.80 /.99
Version 1.0
[
50
]
SAV 220.76 /SAV 242.92 /SAV 243.70 /.71 /
SAV 243.72 /.73 /.76 /.77 /.78 /.79 /.80 /.99
3 TECHNICAL SPECIFICATIONS
Magnet
SAV
243.76
SAV
243.77-27,5
SAV
243.77-55
SAV
243.77-85
SAV
243.78
SAV
243.79
SAV
243.80
Pole pitch P
crosswise,
35/65/85 mm
crosswise,
27.5 mm
crosswise,
55 mm
crosswise,
85 mm
round
hexagonal
poles
square pole
Wear layer of the
pole plate
8 mm
8 mm
8 mm
8 mm
12 mm
8 mm
1 mm (up to
steel insulation)
5 mm (up to
functional limit
in epoxy)
Rated holding force
80 N/cm²
for P = 35
100 N/cm²
for P = 65
160 N/cm²
for P = 85
110 N/cm²
150 N/cm²
170 N/cm²
3200 N/pole
(when using
pole extensions)
900 kN/m²
(for direct
placement)
150 N/cm²
(on workpiece)
900 daN (per
pole pair)
3500 N/pole
(epoxy)
3150 N/pole
(full metal)
195 N/cm
2
on inducible steel surface
Magnet voltage
360 V
360 V
360 V
360 V
360 V
360 V
360 V
Max. magnet current
30 A
up to
610 x 400
for P = 65/85
60 A
up to
600 x 400
for P = 35;
up to
980 x 500 for
P = 65/85
60 A x 2
up to
1000 x 500
for P = 35
30 A up to
630 x 200
60 A up to
800 x 300
60 A x 2 up to
1015 x 500
60 A x 3 up to
1180 x 500
30 A up to
810 x 400
60 A up to
1140 x 500
60 A x 2 up to
2020 x 500
30 A up to
750 x 300
60 A up to
1090 x 600
60 A x 2 up to
1600 x 600
30 A up to
800 x 440
60 A up to
1000 x 525
(linear pole
pattern)
60 A up to
1600 x 600
(offset pole
pattern)
60 A x 2 up to
2000 x 800
(linear pole
pattern)
60 A x 2 up to
2000 x 610
(offset pole
pattern)
60 A x 3 up to
2000 x 800
(offset pole
pattern)
30 A up to
630 x 450
60 A x 2 up to
920 x 500
19 A up to
340 x 360
25 A up to
490 x 360
27 A up to
640 x 360
50 A up to
790 x 360
55 A up to
790 x 480
Cable cross section
3 x 1.5 mm
2
for 30 A
3 x 2.5 mm
2
for 60 A
5 x 2.5 mm
2
for 60 A x 2
3 x 1.5 mm
2
up to
630 x 200
5 x 1.5 mm
2
up to
800 x 300
6 x 1.5 mm
2
up to
1015 x 500
5 x 2.5 mm
2
up to
1180 x 500
3 x 1.5 mm
2
up to
810 x 400
5 x 1.5 mm
2
up to
1030 x 500
5 x 1.5 mm
2
up to
2020 x 500
3 x 1.5 mm
2
up to
750 x 300
5 x 1.5 mm
2
up to
1090 x 600
3 x 2.5 mm
2
for 1600 x 400
5 x 1.5 mm
2
up to
1430 x 600
6 x 1.5 mm
2
up to
1600 x 600
3 x 1.5 mm
2
up to
800 x 400
3 x 2.5 mm
2
up to
1000 x 525
5 x 2.5 mm
2
up to
2000 x 800
3 x 1.5 mm
2
up to
350 x 350
3 x 2.5 mm
2
up to
630 x 410
5 x 2.5 mm
2
up to
770 x 470
3 x 2.5 mm
2
The stated holding force per workpiece area refers to a test workpiece with 100 x 100 x 40 mm made of steel
1.0037 with polished surface. If the application involves other conditions, the achievable holding forces may be
reduced substantially.