![Sargent and Greenleaf Touchless ADO Installation Manual Download Page 38](http://html1.mh-extra.com/html/sargent-and-greenleaf/touchless-ado/touchless-ado_installation-manual_1199136038.webp)
SARGENT & GREENLEAF
■
WWW.SARGENTANDGREENLEAF.COM
[t] 800.826.7652
■ 859.885.9411 ■
E-mail: (Information Required)
■
One Security Dr. Nicholasville, Kentucky 40356
S&G TOUCHLESS ADO.docx REV - 08/2021
38
STEP 9:
ADJUSTING TIMERS ON ADJUSTMENT BOARD
LEGEND:
B1
– Battery – use CR1216 battery – required to maintain timer settings and date programmed by the TAP
TR1
– Opening speed adjustment. Increase speed by turning clockwise = decrease open cycle time
TR2
– Closing speed adjustment. Increase speed by turning clockwise = decrease open cycle time
TR3
– Hold-open time adjustment
TR4
– Closing speed adjustment when power is OFF
TR4
will only be enabled when jumper J6 is moved to the correct
pins. (It is enabled by default).
J2
– USB port
J4
– Ribbon cable connector between boards
J5
– Motor Connector
J7
– Power supply connector between boards
SW1
– Adjustment board “reset”
SW2
– 10 Position “Functions” Dip Switch
For adjustments beyond those mentioned herein, consult the factory.
HELPFUL NOTES:
•
Speed/time and Dip Switch adjustment changes will not take effect until the door closes fully
after the adjustment has been made
AND amber light DL4 is cleared by pressing the switch next
to DL4.
•
Hold Open time affects the delay following activation from input 10, 11, and 13.
•
When Dip Switch 5 is ON, the blue speed and time potentiometers are disabled.