STEP 6 Cont.:
POWER ON & TUNE-IN
•
Perform an initial setup at the I/O board as follows
:
o
E
nsure main power is on
o
At the I/O control board, depress the SW1 button for approximately 5 seconds. When
the red LED (LD2) at the Adjustment Board begins flashing rapidly, release the button.
o
Door will slowly go open, recycle partially, close and then re-open.
o
Do not interrupt the process and do not move the door manually during this time.
o
If the door does not open and the red LED (LD2) is flashing slowly, check to make sure
the motor is plugged in properly at the control board. Correct as necessary.
o
Once the setup process is complete, the door will close and the LED will go out.
o
Setup is complete.
IMPORTANT NOTE: If the operator stroke is altered in any way, a re-learn
must be accomplished.
•
Upon completion of the Setup, momentarily jumper terminals 7 & 11 to activate the door to
open and ensure all performance is acceptable.
•
Go to Step 7. Adjust dip switches for your specific application.
•
Go to Step 8. Connect activation and ancillary devices as required.
•
Go to Step 9. Adjust opening and closing speeds, and door hold open time as necessary. If
speeds are changed, a re-learn is not required.
•
A re-learn is not required following a main power recovery.