16
Before reinstalling the motor, take notice of the location of the 4 mounting hex bolts, and the nut for the 5
th
mounting bolt
Place and Hold the motor assembly up to the header, allowing it rest on the slotted tracks.
Slide in the 4 outer hex bolts and tighten loosely. Slide the entire assembly left or right to line up the 5
th
hex
bolt nut with the mounting hole from the bolt removed on page 5 (near the transformer). Reinsert the hex
bolt and washers removed on page 5.
Temporarily remove one of the mounting hex bolts and washers from the I/O board side of the assembly to
allow the ground wire ring connector to be reconnected.
After all 5 hex bolts have been inserted, reposition the whole assembly so that the spindle attachment point
is centered with the spindle cutout, as shown on the bottom of page 5. Secure the motor assembly by
tightening all 5 hex bolts.
Reconnect the ON-Auto-OFF connector to the I/O board and the molex main power connector.