Double Mount Installation - Round Metal Clock

Dual-mount pole, including 
mounting plate and adapters

#10-32x3/8 green screw

1

1

Description

SAP round analog clock

Mounting Bracket

Quantity

2

(not used)

Picture

Included in Package

Included in Double Mount Kit (SAB-4BD-12R-0 or SAB-4BD-16R-0)  
     (SAB-4BD-12R-0M 

or 

SAB-4BD-16R-0M)

Included in Wiring Kit (A-MK-QS-1E)

#6-32x1/2 screw

M4-0.5x10

#10x1.5 Self-tapping screw

Wall anchor

(not used)

(not used)

(not used)

(not used)

PLEASE NOTE:

 A user will also have to provide a Phillips-head screwdriver, a small slot-head screwdriver, a drill with a 1/4 inch drill bit, a pencil, a double 

gang box, four wall anchors (must support 50 lbs, #8 screw size, 1.5”(3.8cm) screw length), four #8 screws for the wall anchors, four #6-32x1 screws for 
attaching the mounting plate to the gang box, any equipment needed to install the gang box, at least two CAT5 or CAT6 patch cables, and any additional 
network cables or devices needed to provide Power over Ethernet, and a connection to an NTP server.

If any of the items listed in the kits are missing, you may contact your dealer and order a replacement kit.

Complete the section “Preparing to Install” before mounting the clock on the wall.

Summary of Contents for SAP Series

Page 1: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com Current as of April 2016 SAP Series IP Clock Installation Manual V6 7 ...

Page 2: ...nt Installation Round Metal Clock 13 15 Round SlimLine Clock 16 19 Round Aluminum Wood Clock 20 24 Square Clock 25 28 Flag Mount Installation Round Metal Clock 29 34 Round SlimLine Aluminum Clock 35 40 Square Clock 41 46 Double Mount Installation Round Metal Clock 47 51 Round SlimLine Aluminum Clock 52 57 Square Clock 58 64 IP Monitor Software Main Screen 65 Task Bar Options 66 68 I Quick Access M...

Page 3: ... Take precautions to avoid injury by potential safety hazards near the point of installation including but not limited to heavy machinery sharp objects hot surfaces or exposed cables carrying an electric current Follow all mounting instructions exactly as stated in this manual Failure to do so may result in the device falling off the point of installation Packaging materials and mounting items inc...

Page 4: ...k movement If your part number begins with SAP 1 you own a METAL clock If your part number begins with SAP 4 you own a SLIMLINE or SQUARE clock If your part number begins with SAP 5 you own an ALUMINUM clock If your part number begins with SAP 6 you own a WOOD clock Example part numbers SAP 1BS 16R 1 METAL clock SAP 4BS 12S 4 SQUARE clock SAP 4BS 12R 4 SLIMLINE clock SAP 5AS 09R 1 ALUMINUM clock S...

Page 5: ... The Internet A firewall that is open on Ports 80 123 and 1777 At least one laptop or desktop computer with access to this LAN and a web browser A router for the LAN that operates on the subnet 192 168 0 A copy of the Monitor exe program Security access to all of the above items A crossover cable and PoE injector for programming the clocks A means of keeping a record of the clock serial numbers lo...

Page 6: ...sage range of 0 44 to 3 84 watts Connecting when using a PoE Switch 1 Plug in the PoE switch to a power outlet 2 Using a CAT5 or CAT6 patch cable connect one end to the switch router on the network and the other end to the IP clock Connecting when using a PoE Injector 1 Plug in the power injector to a power outlet 2 Using a CAT5 or CAT6 patch cable connect one end to the a switch router on the net...

Page 7: ...d the CD into your computer s CD Drive b Open the file on the CD and select the IPMONITOR application file c Copy the file to your IP Monitor folder 3 If you received the IP Monitor as a web download a Locate the IPMONITOR application file in your computer s Downloads folder b Select the file and copy it to your IP Monitor folder 4 If you received the IP Monitor as an email attachment a Refer to y...

Page 8: ...e clock is set to DHCP by default This means that once the clock is connected to the network it is assigned the next available IP address If a user wishes to access the web interface while the clock is in DHCP mode then the monitor exe program is required The clock can then be identified from its serial number and then double clicked on to enter the web interface If the user decides to use DHCP an...

Page 9: ... performed 1 Use a crossover cable to attach the SAP clock to a PoE injector and the injector to your computer a If you are connecting from the clock to the computer using a PoE switch the injector is not needed 2 If you know the IP address for your clock enter it into the address bar of a web browser to access the clock s Web Interface a If you do NOT know the IP address for your clock power down...

Page 10: ...mation The numbers you enter should be supplied by your network administrator 7 Next to DNS Router set an appropriate IP address The address you enter should be supplied by your network administrator 8 Next to IP Address set an appropriate IP address The address you enter should be supplied by your network administrator Do NOT use 192 168 0 123 9 Write the Clock Number IP Address and intended inst...

Page 11: ...hould take you to the web interface for that clock Use the password 6063 to enter 2 Select the Clock Settings tab enter an easy to identify name for the clock like the clock s location select the GMT offset for your time zone for example New York is 5 and press the submit button Preparing to Install Quick Start S y n c h r o n i z e d C l o c k S y s t e m s S y n c h r o n i z e d C l o c k S y s...

Page 12: ...manual for instructions on how to set the master clock to a static IP address Use the circle next to the textbox to select it and make sure that the Rotate Servers box is unchecked Press the submit button when finished Please Note Regardless of what server or master clock you are using as a time source you must still set the GMT Offset and DST settings in your secondary clocks separately 4 Close t...

Page 13: ...crew Wall anchor 2 2 1 1 PLEASE NOTE A user will also have to provide a Phillips head screwdriver a small flat blade screwdriver a drill with a 1 4 inch drill bit a pencil a single gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of ...

Page 14: ...g box The gang box should be at the bottom of the mounting piece 17 Minimum 43 2 cm 2 Run a CAT5 or CAT6 patch cable from a PoE switch or PoE injector to the gang box Confirm that the switch or injector as well as the master clock are connected to your network router 4 Use the pencil to mark the location of the large circular hole at the top of the mounting bracket Once finished remove the mountin...

Page 15: ...through the top and bottom holes on the clock followed by the top and bottom holes of the mounting bracket 7 Attach the clock to the mounting piece so that the hole at the top of the clock lines up with the hole at the top of the mounting piece and the hole at the bottom of the clock lines up with the hole at the bottom of the mounting piece 1 2 6 Remove the gearbox pin then attach the patch cable...

Page 16: ...E NOTE A user will also have to provide a Phillips head screwdriver a small flat blade screwdriver a drill with a 1 4 inch drill bit a pencil a single gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of the items listed in the wiring...

Page 17: ...ttach the mounting piece to the gang box proceed to step 4A Otherwise go to step 5 Ceiling Minimum 4A If you do not wish to attach the mounting piece to a gang box place the mounting piece on the wall Leave at least 4 inches between the middle of the mounting piece and ceiling Confirm that the bottom of the mounting piece is level with the floor 4 Minimum 2 Run a CAT5 or CAT6 patch cable from a Po...

Page 18: ...Use a pencil to mark the positions of the top two holes then use the 1 4 inch drill bit to drill holes at the locations of the two marks 4C Insert the wall anchors into the two holes then place the two self tapping screws through the mounting piece and into the wall anchors Skip step 5 and go directly to step 6 1 2 6 Remove the gearbox pin then attach the patch cable to the port on the right side ...

Page 19: ...snapping noise as the latch engages 9 If you need to take the clock off the wall after the installation has been completed use a flat blade screwdriver or eyeglasses screwdriver to press down on and release the mounting piece latch then slide the clock off the mounting piece 7 Lay any excess wiring across the strain relief base then attach the strain relief to the clock with the two 6 19x7 16 scre...

Page 20: ...ew Wall anchor 2 2 PLEASE NOTE A user will also have to provide a Phillips head screwdriver a small flat blade screwdriver a drill with a 1 4 inch drill bit a pencil a single gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of the it...

Page 21: ...he floor Ceiling Minimum 3 Insert the release lever into the hole atop the mounting piece latch 4 If you do not wish to attach the mounting piece to the gang box proceed to step 5A Otherwise go to step 6 2 Run a CAT5 or CAT6 patch cable from a PoE switch or PoE injector to the gang box Confirm that the switch or injector as well as the master clock are connected to your network router KNOW YOUR NE...

Page 22: ...the mounting piece is level with the floor 5B Use a pencil to mark the positions of the top two holes then use the 1 4 inch drill bit to drill holes at the locations of the two marks 4 Minimum 5C Insert the wall anchors into the two holes then place the two self tapping screws through the mounting piece and into the wall anchors Skip step 6 and go directly to step 7 6 Place the mounting piece on t...

Page 23: ...n finished reattach the mounting piece 10 Attach the clock to the mounting piece by sliding the clock back onto it You should hear a snapping noise as the latch engages 1 2 8 Remove the gearbox pin then attach the patch cable to the port on the right side of the movement If the clock is able to access the Internet it will begin to correct itself Make a note of the clock s Serial Number which shoul...

Page 24: ...elease lever down then slide the clock off the mounting piece 11 Place one of the self tapping screws through the hole in the top of the release lever 13 If you need to take the clock off the wall after the installation has been completed AND you accidentally broke off the release lever or forgot to attach it during installation take a thin flathead screwdriver thin ruler or eyeglass screwdriver a...

Page 25: ... will also have to provide a Phillips head screwdriver a small flat blade screwdriver a drill with a 1 4 inch drill bit a pencil a single gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of the items listed in the wiring kit are miss...

Page 26: ... about 1 8 inch into each of the slot holes until the housing detaches You may hear a snapping noise as the latches disengage 4 Release the mounting piece from the back of the housing by sliding it towards the center of the housing then pulling it back and away from the housing Mounting piece Housing 1 2 2 Run a CAT5 or CAT6 patch cable from a PoE switch or PoE injector to the gang box Confirm tha...

Page 27: ...ach the mounting piece to the gang box 6 Attach the mounting piece to the gang box using both of the 6 32x1 screws and a Phillips head screwdriver 8 If you wish to prevent the clock from sliding off the mounting piece use the small silver 6 19x3 8 screw on the bottom centered hole Once the screw is in place test it by attempting to slide the housing up The housing should not move 5 Thread the patc...

Page 28: ...g and tightening the screws 12 If you feel the need to take the clock off the wall after the installation has been completed use a flat blade screwdriver to detach the housing from the back of the clock then use a Phillip s head screwdriver to detach the mounting piece from the housing and gang box 1 2 9 Remove the gearbox pin then attach the patch cable to the port on the right side of the moveme...

Page 29: ...ing Bracket Quantity 1 1 not used Picture Flag Mount Installation Round Metal Clock If any of the items listed in the kits are missing you may contact your dealer and order a replacement kit Continued on next page Included in Package Included in Wiring Kit A MK QS 1E 6 32x1 2 screw M4 0 5x10 10x1 5 Self tapping screw Wall anchor 2 not used 2 not used 1 not used 1 not used ...

Page 30: ...e a Phillips head screwdriver a small slot head screwdriver a drill with a 1 4 inch drill bit a pencil a double gang box four wall anchors must support 50 lbs 8 screw size 1 5 3 8cm screw length four 8 screws for the wall anchors four 6 32x1 screws for attaching the mounting plate to the gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional ...

Page 31: ...ing plate from the mounting pole by unscrewing the two screws Set the screws and pole aside for later Ceiling 11 Minimum 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the pencil to trace the locations of the four larger holes at the outer corners 2 Run a CAT5 or CAT6 patch cable from a PoE switch or PoE injec...

Page 32: ...s into the holes 7 Thread any wiring through the mounting plate and attach a grounding wire to the mounting plate using one of the larger centered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 8 screws then insert the four 6 32x1 screws through the mounting plate and into the anchors 8 Use a screwdriver to remove one of the end caps The end cap an...

Page 33: ...f the pole to the mounting plate so that the lip is on the top of the base and the holes for the screws are on the bottom of the base Hang the base on the mounting plate attach the wires from the bottom of the pole to the wires in the gang box then screw the other side of the base onto the mounting plate using the two black screws you set aside before 9 Insert the four 8 32x7 16 screws through the...

Page 34: ...ial Number which should be on a white sticker above the port Add this information to your tracking chart 13 Remove the outer adapter screws then slide the clock onto the adapter in the rotation that you wish it to be viewed You should hear a snapping noise as the four clips on the adapter secure the clock in place Insert the screws again to complete the installation 14 If you feel the need to deta...

Page 35: ... 4 Dual mount pole including mounting plate 10 32x3 8 green screw 1 1 Description SAP round SlimLine analog clock Quantity 1 Picture Included in Package Included in Pole Kit SAB 4BD 00S 0 or SAB 1BD 00S 0 Included in Adapter Kit A SLM MOUNT 12S 0 If any of the items listed in the kits are missing you may contact your dealer and order a replacement kit Continued on next page Included in Gang Box Ki...

Page 36: ...chors must support 50 lbs 8 screw size 1 5 3 8cm screw length four 8 screws for the wall anchors four 6 32x1 screws for attaching the mounting plate to the gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of the items listed in the k...

Page 37: ...h the wall and ceiling 3 Detach the mounting plate from the mounting pole by unscrewing the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the pencil to trace the locations of the four larger holes at the outer corners Ceiling 11 Minimum 2 Run a CAT5 or CAT6 p...

Page 38: ...anchors into the holes 7 Thread any wiring through the mounting plate and attach a grounding wire to the mounting plate using one of the larger centered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 6 32x1 screws then insert the four 8 screws through the mounting plate and into the anchors 8 Use a screwdriver to remove one of the end caps The end ...

Page 39: ...ng plate attach the wires from the bottom of the pole to the wires in the gang box then screw the other side of the base onto the mounting plate using the two black screws you set aside before 10 Thread at least fifteen inches 38 1cm of wiring from the gang box through the bottom of the pole until the cable exits through the hole in the adapter 9 Insert the four 8 32x7 16 screws through the intern...

Page 40: ...his information to your tracking chart 13 Lay any excess wiring across the strain relief base then attach the strain relief to the clock with the two 6 19x7 16 screws The strain relief should be tight enough to prevent the wire from sliding 14 Slide the clock onto the adapter in the rotation that you wish it to be viewed You should hear a snapping noise as the four clips on the adapter secure the ...

Page 41: ... inch drill bit a pencil a double gang box four wall anchors must support 50 lbs 8 screw size 1 5 3 8cm screw length four 8 screws for the wall anchors four 6 32x1 screws for attaching the mounting plate to the gang box any equipment needed to install the gang box at least one CAT5 or CAT6 patch cable and any additional network cables or devices needed to provide Power over Ethernet and a connecti...

Page 42: ...l and ceiling 3 Detach the mounting plate from the mounting pole by unscrewing the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the pencil to trace the locations of the four larger holes at the outer corners Ceiling 11 Minimum 2 Run a CAT5 or CAT6 patch cabl...

Page 43: ...through the mounting plate and attach a grounding wire to the mounting plate using one of the larger centered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 6 32x1 screws then insert the four 8 screws through the mounting plate and into the anchors 8 Detach the housing from the back of each clock Do this by inserting a flat blade screwdriver about ...

Page 44: ...ng then pulling it back and away from the housing You will not need the mounting pieces later either store them or throw them away at your discretion DO NOT THROW AWAY THE HOUSINGS 10 Attach the clock housing to the pole using four black 8 32x7 16 screws and four internal tooth washers 11 Thread at least fifteen inches 38 1cm of wiring from the gang box through the bottom of the pole until the cab...

Page 45: ...in the gang box then screw the other side of the base onto the mounting plate using the two black screws you set aside before CEILING WALL 1 2 1 2 14 Loosen the strain relief by unscrewing the two screws Slip any excess wiring through them then tighten the strain relief by reinserting and tightening the screws 1 2 13 Remove the gearbox pin then attach the patch cable to the port on the right side ...

Page 46: ...clock so that it is right side up Slide the clock back into its housing You should hear a snapping noise as the latches reengage 16 If you feel the need to detach the clock from the housing after the installation has been completed use a flat blade screwdriver on the four slots around the outside of the housing You may hear a snapping noise as the internal latches disengage WALL CEILING ...

Page 47: ... not used 2 not used 2 not used PLEASE NOTE A user will also have to provide a Phillips head screwdriver a small slot head screwdriver a drill with a 1 4 inch drill bit a pencil a double gang box four wall anchors must support 50 lbs 8 screw size 1 5 3 8cm screw length four 8 screws for the wall anchors four 6 32x1 screws for attaching the mounting plate to the gang box any equipment needed to ins...

Page 48: ...ting plate from the mounting pole by unscrewing the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the pencil to trace the locations of the four larger holes at the outer corners Ceiling 11 Minimum 2 Run a CAT5 or CAT6 patch cable from a PoE switch or PoE inje...

Page 49: ...nting plate and attach a grounding wire to the mounting plate using one of the larger centered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 8 screws then insert the four 6 32x1 screws through the mounting plate and into the anchors 8 Thread at least fifteen inches 38 1cm of wiring from the gang box through the bottom of the pole until each cable ...

Page 50: ...ase on the mounting plate attach the wires from the bottom of the pole to the wires in the gang box then screw the other side of the base onto the mounting plate using the two black screws you set aside before 1 2 WALL 1 2 CEILING 1 2 10 Remove the gearbox pin then attach a patch cable to the port on the right side of each movement If the clock is able to access the Internet it will begin to corre...

Page 51: ...ck onto the adapter in the rotation that you wish it to be viewed You should hear a snapping noise as the four clips on the adapter secure the clock in place Insert the screws again to complete the installation 12 If you feel the need to detach the clock from the housing after the installation has been completed remove the outer adapter screws press down on the latches and gently pull on the rim o...

Page 52: ...nting plate 10 32x3 8 green screw 1 1 Description SAP round SlimLine analog clock Quantity 2 Picture Included in Package Included in Double Mount Kit SAH 4BD 12R 0 or SAH 4BD 16R 0 SAH 1BD 12R 0 or SAH 1BD 16R 0 Included in Mounting Kits A SLM MK S 1 or A SLM MK AW Double Mount Installation Round SlimLine Aluminum Clock If any of the items listed in the kits are missing you may contact your dealer...

Page 53: ...th a 1 4 inch drill bit a pencil a double gang box four wall anchors must support 50 lbs 8 screw size 1 5 3 8cm screw length four 8 screws for the wall anchors any equipment needed to install the gang box at least two CAT5 or CAT6 patch cables and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of the items listed in the kits ...

Page 54: ...th the wall and ceiling 3 Detach the mounting plate from the mounting pole by unscrewing the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the pencil to trace the locations of the four larger holes at the outer corners Ceiling 11 Minimum 2 Run a CAT5 or CAT6 ...

Page 55: ...into the holes 7 Thread any wiring through the mounting plate and attach a grounding wire to the mounting plate using one of the larger centered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 6 32x1 screws then insert the four 8 screws through the mounting plate and into the anchors 8 Thread at least fifteen inches 38 1cm of wiring from the gang bo...

Page 56: ... base on the mounting plate attach the wires from the bottom of the pole to the wires in the gang box then screw the other side of the base onto the mounting plate using the two black screws you set aside before 1 2 1 2 WALL CEILING 1 2 1 2 1 2 10 Remove the gearbox pin then attach a patch cable to the port on the right side of each movement If the clock is able to access the Internet it will begi...

Page 57: ...e four clips on the adapter secure the clock in place 11 For each clock lay any excess wiring across the strain relief base then attach the strain relief to the clock with the two 6 19x7 16 screws The strain relief should be tight enough to prevent the wire from sliding 13 If you feel the need to detach the clock from the housing after the installation has been completed use a flat blade screwdriv...

Page 58: ... 10 32x3 8 green screw 8 32x7 16 screw M3 5 1 0x10 screw black Internal tooth washer 1 1 8 4 8 Description SAP square analog clock Mounting Piece already attached to clock housing Quantity 2 2 not used Picture Included in Package Included in Pole Kit SAB 4GD 00S 0 or SAB 1GD 00S 0 If any of the items listed in the kits are missing you may contact your dealer and order a replacement kit Continued o...

Page 59: ... inch drill bit a pencil a double gang box four wall anchors must support 50 lbs 8 screw size 1 5 3 8cm screw length four 8 screws for the wall anchors any equipment needed to install the gang box at least two CAT5 or CAT6 patch cables and any additional network cables or devices needed to provide Power over Ethernet and a connection to an NTP server If any of the items listed in the kits are miss...

Page 60: ...ll and ceiling 3 Detach the mounting plate from the mounting pole by unscrewing the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the pencil to trace the locations of the four larger holes at the outer corners Ceiling 11 Minimum 2 Run a CAT5 or CAT6 patch cab...

Page 61: ... through the mounting plate and attach a grounding wire to the mounting plate using one of the larger centered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 6 32x1 screws then insert the four 8 screws through the mounting plate and into the anchors 8 Detach the housing from the back of each clock Do this by inserting a flat blade screwdriver about...

Page 62: ... You will not need the mounting pieces later either store them or throw them away at your discretion DO NOT THROW AWAY THE HOUSINGS 10 Attach both housings to the pole using four black 8 32x7 16 screws and four internal tooth washers on each side 11 Attach the housings to each other using the four black M3 5 1 0x10 screws two on each housing 12 Thread at least fifteen inches 38 1cm of wiring from ...

Page 63: ...se on the mounting plate attach the wires from the bottom of the pole to the wires in the gang box then screw the other side of the base onto the mounting plate using the two black screws you set aside before CEILING WALL 1 2 1 2 1 2 14 Remove the gearbox pin then attach a patch cable to the port on the right side of each movement If the clock is able to access the Internet it will begin to correc...

Page 64: ... the latches reengage 17 If you feel the need to detach the clock from the housing after the installation has been completed use a flat blade screwdriver on the four slots around the outside of the housing You may hear a snapping noise as the internal latches disengage WALL CEILING 15 For each clock loosen the strain relief by unscrewing the two screws Slip any excess wiring through them then tigh...

Page 65: ...ot available with IP analog clocks 5 Download Configuration to Clocks If a configuration file was created using Upload and Save Configuration on the Quick Access Menu this option lets the user apply the configuration file to other clocks highlighted within the monitor Pressing this button will cause the Download Configuration window to appear A Enter Password The Password is 6063 B Select Configur...

Page 66: ...will cause the monitor to display all of the IP devices in that group Example Clicking on Group 1 will cause the monitor to show only the devices that have been added to Group 1 through the Configure Groups menu Configure Groups Opens the group configuration menu see below A Text Boxes Entering a name into the text box will change the name of the group For example the first text box currently cont...

Page 67: ...r By Clock Type By selecting this option the user is able to view specific clock types on the Monitor Screen The clock types users can filter through are Master Clocks Network Repeaters IP Analog and or IP Digital clocks When the box next to the clock type is checked the user will be able to view that clock type on the Monitor Screen Filter By Name By selecting this option the user is able to sear...

Page 68: ...ntered Send Test Email By selecting this option the user is able to send a test email to the email address specified in the Configure Email Alerts option 5 Databases When clicked this button will display the following options Download Configuration By selecting this option the user can load an IP clock s setting from a PC to another IP clock Upload Configuration By selecting this option the user c...

Page 69: ...not available with IP analog clocks 6 Send Looping Message to Clocks This option is not available with IP analog clocks 7 Send Numeric Message to Clocks This option is not available with IP analog clocks 8 Download Configuration to Clock If a configuration file was created earlier using Upload and Save Configuration this option lets the user apply the configuration file to the highlighted device R...

Page 70: ...ck have turned gray then the clock was once displayed on the IP Monitor but upon launching the IP Monitor program this most recent time the clock cannot be found on the network 3 Characters are Black When the characters of a clock are black this means that the clock is working normally 4 Unknown MAC Address An IP device with older software will report its MAC address as Unknown This is a result of...

Page 71: ...m will check the password If the password is correct it will grant the user access to the Web Interface 1 Welcome Sign Displays the Clock name 2 Time Displays the clock s time at the moment the web page was loaded This information does not update unless the page is refreshed 3 Date Displays the clock s date at the moment the web page was loaded This information does not update unless the page is r...

Page 72: ... to be made 5 Clock Name Allows the user to set a unique name for the clock so that it can be identified on the IP monitor The name must be fewer than 20 characters 6 Clock Number Displays the serial number for the clock so that it can be identified on the IP monitor This number cannot be modified 7 Network Sync Every Allows the user to select how often the clock should attempt to synchronize with...

Page 73: ... New York is an offset of 5 and Hong Kong is an offset of 8 10 Dial State This setting allows the user to correct the clock The three options may be activated via the drop down menu 11 Submit Applies any changes to the previous options when pressed Passwords must be fewer than 16 characters and may only use English uppercase letters A Z lowercase letters a z or the digits 0 9 Entering a password t...

Page 74: ...rver If DHCP is disabled then the user may set their own static IP address 5 MAC Address This field shows the clock s permanent machine address It cannot be changed 6 DHCP Allows the user to set whether or not the clock will use a DHCP server to determine the IP address for the clock 7 Broadcast to Monitors Allows the user to set whether or not the clock may send data to the IP Monitor 8 Send Spec...

Page 75: ...lock 2 Server Addresses These fields allow a user to set the address that the clock will use to obtain NTP time Web addresses may be entered as a URL or IP number 3 Rotate Servers When left unchecked the clock will only attempt to obtain time from the selected NTP server and will only attempt to try other servers if the selected server fails When checked the clock will rotate through the listed ad...

Page 76: ...es additional details about NTP synchronization when clicked 2 Resync NTP Now This button forces a synchronization with the NTP server when clicked 3 Reset NTP History This button resets all of the data in the NTP details window when clicked 4 Reset Adjustment Data This button resets the statistics of previous time drifts when checked 1 3 2 4 S y n c h r o n i z e d C l o c k S y s t e m s ...

Page 77: ...bmit to apply the settings to the clock Example Second Sunday of March at 2 00 Day of the Month This mode allows the user to select the specific day of the month and time for when the clock will switch to daylight saving time Once the date month and time are set click Submit to apply the settings to the clock Example March 1st at 2 00 By Country This mode allows the user to select preset Daylight ...

Page 78: ...IELDS 1 2 AND 3 MUST BE COMPLETED FOR THE EMAIL FEATURE TO FUNCTION 4 Email Alert NTP Synchronization Timeout When selected the clock will send an email alert if the clock hasn t received a time synchronization after the number of minutes listed in the field next to the selection box 5 Email Alert Time Sync Change When selected the clock will send an email alert whenever the difference between the...

Page 79: ...ompany Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 1 Clear Log When clicked this button deletes all of the information on the Log page Web Interface Log 1 ...

Page 80: ... If a user wishes to apply the changes from one web interface to all clocks on the system they may do so through the IP monitor program How many power injectors will I need if I am installing the clocks using Power over Ethernet PoE Each clock will need an injector however there are products that exist such as PoE switches which provide multiple PoE ports What type of cable is used for PoE PoE is ...

Page 81: ... correct IP address If you were using the correct IP address reexamine your network firewall for settings that could prevent you from accessing the clock The clock is not showing the right time What should I do Attempt the following corrections in numerical order until the clock properly synchronizes 1 Confirm that the clock is on the network by finding it with your IP monitor 2 Confirm that the c...

Page 82: ... by The Sapling Company Inc To Goods which are altered modified or repaired in any place other than a Sapling Company Inc factory or by persons not expressly authorized or approved in writing by The Sapling Company Inc THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WITH RESPECT TO GOODS DELIVERED UNDER THIS CONTRACT WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION A...

Reviews: