ALARM SETTING
ALARM item flow
The following settings are necessary for alarm detection.
•
Connect the supplied alarm input expansion connector to the
alarm input connector, then connect the external alarm
(contactless) switch to the end of it.
•
In the menu for preset positions, select a preset position from 1
to 8. (Preset positions 9 and higher cannot be used for alarm
detection.)
•
By setting the MOTION SENSOR for the preset position (1 – 8),
external alarms and motion sensing can be detected at the
same time.
A ALARM IN (ALARM) (See p46)
Make settings for time of alarm input. In the selection screen
ALARM IN field where “1” is shown, an alarm screen number up to
8 can be selected with the joystick lever (
d
or
c
). The ALARM IN
number of the selection screen is linked with the alarm switch
ON/OFF, the preset position (1 - 8) and the MOTION SENSOR.
☞
MOVE MODE
With MOVE MODE, AUTO setting is only possible when MOVE is
set to ON for the corresponding ALARM IN setting screen.
For example, while the preset position is automatically being
switched, set ON for MOVE in the ALARM IN 1 setting screen. In
the next selection screen, select AUTO for MOVE MODE.
If an alarm is detected in this condition, the camera will move to
preset position 1 at the next automatic switch of preset positions,
and after pausing 5 seconds (DURATION initial setting), the
camera will return to the screen in use before the switch.
Note: Operations such as motion zoom will be suspended and
returned to AUTO MODE.
B ALARM OUT (ALARM) (See p47)
Make settings for time of alarm output. In the selection screen
ALARM OUT field where “1” is shown, an alarm screen number up
to 2 can be selected with the joystick lever (
d
or
c
).
When ALARM OUT is set to OFF, alarms cannot be output to
peripheral equipment.
☞
ALARM OUT
For example, when ALARM OUT is set to “1” in the ALARM IN 1
setting screen and ALARM OUT is set to “1” in the selection
screen, the alarm output image becomes the camera image taken
after moving to preset position 1. (If set to ALARM IN 3, image is
from preset position 3.)
By connecting the camera’s alarm output connector (1 or 2) to the
input terminal of a time lapse video recorder or digital video
recorder, the preset position 1 image will be recorded. For alarm
output, be sure to match ALARM OUT number for each ALARM IN
setting screen with the ALARM OUT number in the selection
screen.
C LINE OUT
Sends the alarm signal to the system controller. When this signal is
received, the ALARM indicator lamp on the system controller will
flash. Alarm information such as date/time, camera and alarm type
will be displayed in the alarm list.
ALARM
ALARM IN 8 ‚
ALARM OUT 1 ‚
PRESET OFF
MENU BACK
ALARM
ALARM IN 1 ‚
MOVE MODE OFF
ALARM OUT 1 ‚
PRESET OFF
MENU BACK
ALARM IN 8
POLARITY NO
MOVE OFF
MOTION OFF
ALARM OUT OFF
LINE OUT OFF
DURATION 5S
PRESET OFF
MENU BACK
ALARM IN 1
POLARITY NO
MOVE OFF
MOTION OFF
ALARM OUT OFF
LINE OUT OFF
DURATION 5S
PRESET OFF
MENU BACK
PRESET N
1:0 11:X
2:0 12:X
3:0 13:X
4:0 14:X
5:0 15:X
6:0 16:X
7:0 17:X
8:0 18:X
9:X 19:X
10:X 20:X
C
ALARM
ALARM IN 1 ‚
MOVE MODE OFF
ALARM OUT 1 ‚
ALARM OUT 1
POLARITY NO
ALARM TIME 5S
ALARM
ALARM IN 1 ‚
MOVE MODE OFF
ALARM OUT 2 ‚
ALARM OUT 2
POLARITY NO
ALARM TIME 5S
1
2
3
4
5
6
7
8
MAIN MENU
LANGUAGE SET ‚
PRESET POSITION SET ‚
CAMERA SET ‚
AUTO MODE PAN ‚
AUTO FLIP ON
ALARM OFF
FREEZE OFF
REFRESH OFF
STARTING POINT OFF
MENU END
External alarm switch
(alarm signal source)
Preset Position
setting
☞
☞
B
Alarm output setting
Digital video recorder
(sold separately)
Buzzer or lamp
A
Alarm input setting
(Selection screen)
(Setting screen)
Motion Sensor
setting
Output of alarm
signal to system
controller
(Selection screen)
(Setting screen)
LINE OUT
English
– 45 –