Names of each part and connections
6
Remote systems such as system controllers and PTZ cameras are connected to the RS-485 control terminal.
Check the manufacturer of the units to be connected and connect the units to the appropriate terminal signals (A/B).
This unit can be operated through the controller.
Memo:
• The setting of the RS-485 screen on the system
setting is necessary when a system controller is
connected. (P40)
• Refer to the System controller’s instruction manual
for more information about the operation method.
If a PTZ camera equipped with a RS-485 control terminal is
connected, the camera can be directly operated through this
unit.
Memo:
The settings of the PTZ CONTROL screen and
RS-485 screen on to system setting are necessary
when a camera is connected. (P14, 40)
Connecting to the RS-485 control terminal
1 2 3 4
1
A (SANYO SSP)
To connect a Sanyo PTZ camera or system
controller
2
B (SANYO SSP)
3
A (EXCEPT SANYO)
To connect a third-party camera
4
B (EXCEPT SANYO)
If a system controller is connected
System controller
If a camera is connected