14
-
4‑3
Various measuring methods
MR-300 can be used with the combination of the probes and the following functions as well.
When the Meter is used with the combination of the functions, it is necessary to set up each function.
Set up the necessary function only when the Meter is used.
1)Measurement
→
Indication of the data (Refer to
5‑1
)
2)Measurement
→
Indication of the data and printing (Refer to
5‑7
)
3)Measurement
→
Indication of the data and communication with PC (Refer to
5‑9
)
4)Measurement
→
Indication of the data, printing and communication with PC (Refer to
5‑11
)
5)Measurement
→
Indication of the data and store of the data in the memory (Refer to
5‑13
,
5‑16
)
6)Measurement
→
Indication of the data, store of the data in the memory and printing (Refer to
5‑18
)
7)Measurement
→
Indication of the data, store of the data in the memory and communication
with PC (Refer to
5‑19
)
8)Measurement
→
Indication of the data, store of the data in the memory, printing and communication
with PC (Refer to
5‑20
)
9)Printing of the stored data in the memory (Refer to
5‑21
)
10)Communication with PC of the stored data in the memory (Refer to
5‑22
)
11)Printing and communication with PC of the stored data in the memory (Refer to
5‑23
)
12)Indication of the results statistically treated of the stored data in the memory (Refer to
5‑24
)
13)Indication of the results statistically treated of the stored data in the memory and printing(Refer to
5‑25
)
14)Indication of the results statistically treated of the stored data in the memory and communication
with PC (Refer to
5‑27
)
15)Indication of the results statistically treated of the stored data in the memory, printing and
communication with PC (Refer to
5‑29
)
16)Indication of the histogram drawn by the results statistically treated (Refer to
5‑24
)
17)Indication of the histogram drawn by the results statistically treated and printing (Refer to
5‑26
)
18)Indication of the histogram drawn by the results statistically treated and communication
with PC (data of values) (Refer to
5‑28
)
19)Indication of the histogram drawn by the results statistically treated, printing
and communication with PC (data of values)
(Refer to
5‑30
)
※
Notice: The Meter can be used with the
hold mode only
except 1) item above mentioned.
The Meter indicates [inhibit] (kana:
シヨウキンシ
) on the LCD display
⑰
besides the hold mode and can
not be set. Be sure to press the [HOLD] key
②
.
※
Notice: The Memorized data processing
When the memorized data are processed such as printing out, communication with PC, erase of the
data, etc., the probe dealing with the memorized data must be connected,
otherwise the operation for the memorized data processing can not be carried out.